01-394-0148
Gas Detector
Oxygen/flammable, carbon dioxide/hydrogen sulfide detection; alarms; instantaneous, time weighted average
01-394-1262
Gas Detector
Used on model 1095 leak detector, p/n 1095d100, mfg 19459. 8.250" overall length 4.625" overall width high frequency linear response electron capture detector; detector can be remotely mounted (5 ft) from controls; output is an analog signal suitable for driving a chart recorder or standard digital counter with 0/10 volts; detector temperature range control +160 to 320 deg c.; contains stainless steel detector block, heater block, platinuim resistor temperature sensor, over-temp limit switch; 1/8 in o.d. stainless steel tube 6 in lg.; detection volume 180 milliliters; gas flow 60/100 milliliters per minute of 95 pct argon/5 pct methane or nitrogen or SF6; 2 position switch to optimize pulse width for carrier gas; 16 position recorder output; 10 turn baseline adjustment; power requirement 115 vac 60hz 100 watts; electrical connectors for anode, cathode, frequency output, recorder output, temperature control,
01-394-2569
Scintillator
Used on 6665-01-347-6100. 5.000" overall length 3.990" overall width when sold as spare, must be bonded to gasket p/n A3190349-2.
01-394-2574
Radioactive Test Sample
Used on 6665-01-347-6100. alpha side/ x-ray side
01-394-5312
Gas Detector
Used on ht dds life support. toxic gas detector kit includes approved spare parts, carrying case
01-395-5210
Gas Detector
Used on dds life support. 6.000" overall length 1.000" overall width use for monostyrene gas
01-395-5211
Gas Detector
Used on dds life support. 6.000" overall length 1.000" overall width use for phenol gas
01-395-5212
Gas Detector
Used on dds life support. 6.000" overall length 1.000" overall width use for syclohexane gas
01-395-5213
Gas Detector
Used on dds life support. 6.000" overall length 1.000" overall width tube box, vinyl chloride 0.5/b, 0.5-30 ppm use for vinyl chloride gas
01-395-5215
Gas Detector
Used on dds life support. 6.000" overall length 1.000" overall width use for methylbromide gas
01-395-6889
Air Sampling Pump
Used with part number ATX620
01-395-7042
Radiac Detector
01-397-0075
Chemical Agent Monitor
4.750" overall length 2.750" overall width
01-397-4827
Radiac Detector
Used on infrared mtn.
01-397-7158
Radiac Sample Holder
01-398-7324
Gas Automatic Alarm
Used on detection system.
01-399-3663
Gas Automatic Alarm
Used on gas detecting equipment.
01-399-5940
Radiacmeter
48.0mm overall width includes visual
01-399-7480
Nuclear-bi Reconnaissance System
Used on force provider.
01-400-6116
Gas Detector
Infrared detection system; multiple gas monitoring in one unit; monitors up to 7 areas, expandable to 31 areas with expansion module; compliance with 3 relay output for alarm, spill alarm,
01-400-6119
Gas Detector
Port expansion model for hgm-200 gas monitoring system; 8 two-colored led displays individual status of area monitor; 8 push buttons for manual control to stop automatic sequence or to focus on a particular monitor area; expands gas monitoring system to monitor up to 31 different area locations; automatic or manual sampling mode; 5 seconds to 90 seconds response time depending on air sample, tubing length,
01-406-2199
Chemical Agent Detector Paper
4 bottles per package; 8.25" long; 0.2" wide; for use intesting steris 20 dilution
01-407-1236
Radiac Computer-indicator
Used on an/udr-13.
01-407-1237
Radiac Set
Used on an/udr-13.
01-407-5610
Air Sampler Kit
Model hd-28a air sampler nuclear requirements not needed; collect dust on filter; nsn 4470-01-194-0831 containes special requirments for nuclear application
01-407-8332
Gas Detector Kit
Used on co-82/co-91to;ticonderoga class cg (47). interference filter adapter or seal adapter which is used on a calibration kit for a gas detector
01-407-8333
Gas Detector Kit
Used on co-82/co-91to;ticonderoga class cg (47). test cup for calibration kit which is used on a gas detector kit
01-407-8336
Gas Detector Kit
Used on co95 toxic ga;ticonderoga class cg (47). plastic cylinder case used with a calibration kit
01-407-8337
Sampling Gas Indicator Probe
Used on co95 toxic ga;ticonderoga cl;ass cg (47).
01-407-8338
Gas Detector Kit
Used on co-82/co-91to;ticonderoga class cg (47) cage 38597. 2 liter bag with clamp; part of calibration kit that goes on a portable gas detector
01-407-9535
Carbon Monoxide Indicator
Used on ticonderoga class cg947;toxic gas.
01-408-1701
Water Testing Reagent Set
Item is designed for drinking water concentrations.testing for chemicals found in water; metals
01-408-1787
Radiac Detector
Used on an/udr-13.
01-408-2640
Hazard Dete Test Set Subassembly
Used on control assy, hydrogen detector.
01-408-5108
Chemical Agent Detector
Chemical warfare agent detector qcapable of being installed on vehicles, permenantly installed
01-408-7786
Water Testing Reagent Set
Trace metals; waste water; one 10ml screw-top vial to be diluted to 1 liter
01-411-1272
Gas Detector
Approved for class i, division 1 flammable gases
01-412-0578
Gas Detector
10.800" overall length 8.300" overall width
01-412-6419
Monitor Chemical A Case Assembly
Used on 6665-01-314-2086.
01-414-8722
Radiac Detector Charger
Used on 6665-01-372-1303.
01-414-8723
Radiacmeter Subassembly
Used on 6665-01-392-1303.
01-415-4133
Gas Automatic Alarm
Used on nimitz class cvn;gas detector. model 1400-04
01-415-5123
Radiacmeter
17.325" overall length 17.325" overall width 115.0 ac voltage in volts and current type unit reads out in becquerel
01-416-7938
Radiac Calibrator Set
Used on gas detector.
01-418-1655
Chemical Agent Detector Capsules