Hazard-detecting Instruments And Apparatus FSG 66 — FSC 6665

NSN
NIIN
Name
Details
01-352-7171
Radiac Detector Charger
Used on hazard detecting instruments and apparatus.
01-352-7172
Radiac Set
01-352-7173
Radiac Set
Noisemonitoring set
01-352-7174
Radiacmeter
Used on hazardous detecting instruments and apparatus.
01-352-7274
Radiac Calibrator
Used on hazard detecting instruments and apparatus.
01-352-7898
Radiac Computer-indicator
01-352-9963
Radiacmeter
Used on hazard-detecting instruments/apparatus.
01-353-0150
Chemical Agent Water Testing Kit
01-353-3785
Gas Detector
5.000" overall length graduated, direct-reading glass diffusion tube; carbon dioxide samples are taken at a constant rate
01-353-4882
Chemical Agent Detecting Cell
01-353-6347
Radiac Detector
Liquid scintillation sys
01-353-7700
Chemical Agent Aut Detector Unit
Used on 6665-01-324-6637. c/odetector assy, pn 5-15-10479; cable assy, power electrical, pn 5-15-10488; transit cable assy, pn 5-15-10546
01-354-2258
Chemical Agent Automatic Housing
Used on 6665-01-324-6637. c/ohousing, base pn 5-15-10465; bezel
01-356-9861
Gas Detector Test Set
01-357-0738
Gas Detector Test Set
01-357-3209
Sampling Gas Indicator Probe
01-357-8502
Chemical Agent Monitor
Used on aacz16 z47 and aacz16 z16. consists of one monitor kit, chemical agent monitor p/n 5-15-17042; one confidence sample assembly p/n 442-642; one nozzle protective cap assembly p/N442-674
01-358-3869
Gas Detector
4.500" overall length gacetone (lr) detector tube; hermetically sealed; break off tips; chemically filled to produce a colorimetric indication; measurable concentration range 50-12000dpm; used w/pump, model 800, pn 7010657-1
01-359-9006
Chemical Agent Monitor
01-359-9928
Combustible Gas Portab Indicator
01-360-6907
Gas Detector
01-360-7276
Radiac Detector
Used on radiacmeter,6665-01-320-4712. scintilator zn s (ag) ; 100 cm sq active area; 36 pct (2 pi) efficiency; gamma response 7 cpm/mr/hr; mylar window; 1 dpm/cm sq sensitivity
01-360-7277
Radiac Probe
Used on nsn 6665-01-320-4712 adm300 kit c radiac set. 260.0mm overall length single channel analyzer; active area 9.6 cm sq w/65 pct open area screen; window 12 mg/cm sq thick; scintillator CAF2 (eu) , 3mm thick; gamma response 1.1 x 10 to 4th power per mr/h of cs-137
01-360-7278
Radiac Probe
Used on nsn 6665-01-320-4712 adm300 kit c radiac set and nsn 6665-01-363-6213 adm300 kit a radiac set. 280.0mm overall length 80.0mm overall width model 100; use 5cm pancake gm tube; active area 15 cm sq; window 1.5-2 mg/cm sq; sensitivity 3 dpm/cm sq; energy 100 kev
01-360-8287
Radiacmeter
Used on used in the adm-300 kits a, b and c radiac sets, nsns 6665-01-363-6213, 6665-01-342-7747 and 6665-01-320-4712. 177.0mm overall length 101.6mm overall width 9.0 dc voltage in volts and current type energy response 80 kev-3.0mev gamma; low range tube has 2-3 mg/CM2 end window for beta detection; lcd DISPLAY2X16 dot matrix alpha-numeric; backliggted; rs-232 interface
01-361-4800
Gas Detector Test Set
Used on aircraft oxygen system test set navy model ttu-520/e.
01-361-6066
Radiac Detector
Used on radiac program. items are being coded as critical to insure source inspection will be performed at the point of manufacture, prior to material receipt by the us navy or other dod components. these items are piece parts or end items in support of vital military hardware necessary to sustain the successful mission of the ships, submarines,
01-362-0299
Radiacmeter
Used on a-6 acft.
01-362-5731
Gas Detector
9.000" overall length 4.500" overall width ac btry charger; leather carrying case; liq crystal display; alarms - audio tone
01-362-9913
Gas Detector
Used on msa thumbpump sampling pump,p/n 485675. 6.000" overall length hermetically sealed glass tube; filled w/inert carrier matl which has been impregnated w/a reagent designed to produce a colorimetric indication; measures hydrogen sulfide (H25) ; range of measurement: 1-200 ppm; number of pump strokes: 1 ps for 10-200 ppm, 10 ps for 1-20 ppm; use for direct reading of the quality of air around power plans, sewage
01-363-1348
Gas Detector
01-363-6213
Radiac Set
Portable item; adm 300 kit a; digital analog radiation monitoring system; non-aviation critical safety item
01-363-8847
Radiac Detector
01-364-4953
Detector-cooler Assembly
Used on 6665-01-324-6637 xm21 (rscaal). housing, detector p/n 5-15-10817; plate assy-back p/n 5-15-10814; plate bottom p/n 5-15-10815; retainer lens p/n 5-15-10606; gasket, connector p/n 5-15-10899; mirror, detector p/n 5-15-10818; lens, exit p/n 5-15-10601; gasket, detector/dewar p/n 5-15-10898; cca-preamp p/n 5-15-10871; cooler assy p/n 5-15-10975; detector/dewar assy p/n 5-15-10876; standoff, preamp p/n 5-15-10897; ht snk assy, lin cooler p/n 5-15-10953
01-364-7247
Gas Detector
Used on an/avq-26 nsn 1270-01-347-7904 target designator set. 7.000" overall length 3.000" overall width sensitivity 1/2 oz. per yr; audible tone tone indicates leak; beep speeds up, changes tone when leak is located; 4 aa batteries with 50 hrs life
01-365-5628
Mine Detector Control
01-365-9265
Gas Detector
Used on kd930 oxygen detection and monitoring system. 2.500 in. w; 5.250 in. h; 9.188 in. lg; zero to twenty-five pct oxygen range; std relays; on/off pilot switch (green) ; fail light (blue) ; test switch (amber) ; alarm light (red) ; alarm reset; indicating meter
01-365-9266
Gas Detector
Used on kd930 oxygen detection and monitoring system. K2.500 in. w; 5.250 in. h; 9.188 in. lg; zero to twenty-five pct oxygen range; sealed relays; on/off pilot switch (green) ; fail light (blue) ; test switch (amber) ; alarm light (red) ; alarm reset; indicating meter
01-365-9267
Gas Detector
Used on kd930 oxygen detection and monitoring system. 2.500 in. w; 5.250 in. h; 9.188 in. lg; zero to five pct/zero to twenty-five pct oxygen range; std relays; on/off pilot switch (green) ; fail light (blue) ; twenty-five pct switch (amber) ; alarm light (red) ; alarm reset; indicating meter
01-365-9278
Automatic Chemical Agent Tripod
Used on 6665-01-324-6637.
01-366-2445
Radiac Calibrator Set
Used on PMEL. erange: 0.0 to 12.2"; accuracy: straightness, 0.001 in. per in. 0ftravel; setability: 200 to 220 steps per in.; rate of travel: 0.20 to 0.70 in. per second; table stage area: 10.0in. x 18.0 in.
01-366-5156
Cbr Agents Sampling A Repair Kit
01-367-4634
Gas Detector Test Set
Used on ohio class ssn (trident) ship. 0.750 in. per second; union nut end w/spcl adapter; 8330 psi
01-367-4635
Gas Detector Test Set
Used on ohio class ssn (trident) ship. 0.750 in. per second; union nut end w/spcl adapter; 8330 psi
01-368-1587
Radiac Calibrator
53.000" overall length 48.000" overall width zc/o CS137 source, irradiation chamber shield, source shield, source transport system, interlocks
01-368-3289
Radiac Detector
01-368-6290
Gas Detector
Used on diffusion tube holder,national draeger,inc.,p/n 6733014. detector gas chemical reaction color diffusion tube 10s color diffusion tube; measures carbon monoxide levels 50 to 600 ppm; calibrated scale printed directly on tube; range of measurement for peroid of use (8 hours) is 6.3-75 ppm; used for personal monitoring to measure time-weighted average concentrations for up to 8 hours; unit pkg qty 10
01-369-5243
Gas Detector Kit
Used on an/apq-175 adverse weather aerial delivery system (awads) c-130e acft.
01-370-0545
Radiac Calibrator Set
Chambers: A3 3/8 in radius, 3.6 vol cc, 0.0 r/nc cal factor; A4 - 3/4 in rad, 30 cc volume, 0.09 r/nc cal; A51-1/8 in radius, 100 cc vol, 0.03 r/nccal; A6 - 2-1/4 in. rad, 800 cc vol; 0.004 r/nc cal; laser: 1-6 meters/sec velocity; 2 g's acceleration; distance .17-30 meters; elevataion porm 60 deg; electrometer: 200 mv-200 v range; 10 uv-10 mv resolution; power supply: 0-3 kv dc output; thermometer: 0.1 deg resolution; displays degrees f. or c.; barometer: 0.5-19 psia, 3.5-130 kpaa
01-370-5575
Gas Detector
Page: 17 ...