Combination And Miscellaneous Instruments FSG 66 — FSC 6695

NSN
NIIN
Name
Details
01-118-8794
Instrument Mounting Bezel
Used on 4920-01-054-5641 test station,display indicator.
01-119-9400
Instrument Light
60.0mm overall width
01-120-8915
Instrument Mounting Bezel
01-121-1094
Motional Pickup Transducer
8.000" overall length 4.500" overall width
01-121-1193
Motional Pickup Transducer
5.500" overall length 5.400" overall width
01-121-4040
Motional Pickup Transducer
Output current 4 to 20 milliamperes dc; range 0 to 300 psig; transducer seawater
01-121-7382
Motional Pickup Transducer
Used on aircraft f111.
01-121-7886
Instrument Light
0.860" overall length lighting specifications per mcdonnell-douglas mdc-A4056
01-121-8041
Motional Pickup Transducer
Used on board 270 ft wmec cg vessels. used with 100 ohm platinum resistance temperature detector; temperature span 20 thru 140 degrees centigrade; output o-1 ma
01-122-0083
Motional Pickup Transducer
Used on voltmeter 50-103121 pzsj onboard 270 ft wmec coast guard vessels. 4.000" overall length 2.120" overall width X60 hz center 85-135 vac, max overload 150 vac continuous-200 vac for one minute, burden 120 vac less than 2 va, operating temp range minus 20 degree c to plus 65 degree c, max temp effect plus 0.2 percent of center frequency, output minus 5 to plus 5 ma. into 0-10 k ohms linearity plus or minus 0.02 percent of center frequency, line plus or minus 0.02 percent of center frequency, adjustments-zero plus or minus 10 percent of low frequency min adj. , calibration plus or minus 20 percent of full scale value, ac component of output sg. 1 percent, response time 400 ms, dielectric test 1500 vrms, meets ieee swc surge test, 4 unthreaded mounting holes 0.203 in. dia.. 3.500 in. apart measured lengthwise, 1.500 in. apart measured across width
01-122-2608
Motional Pickup Transducer
C/o housing-transducer 1; connector, male 1; clip 1
01-122-7448
Meter Movement
01-122-7941
Instrument Mounting Bezel
01-122-9531
Motional Pickup Transducer
Used on combination and misc instruments.
01-123-2683
Instrument Mounting Bezel
01-123-2727
Meter Movement
01-123-2728
Meter Movement
01-123-4104
Indicator Housing
Used on f-16 aircraft. 4.610" overall length 3.030" overall width
01-124-0379
Motional Pickup Transducer
Shall measure the airspeed vector
01-124-3240
Primary Referenc Calibration Set
Consists of a pressure gage, digital voltmeter, vacuum gage, vacuum pumbuilt into a 19 in. lg by 14 in wide cabinet, quartz bourdon tube sensor, reads in" of mercury
01-125-1035
Instrument Mounting Bezel
01-125-1143
Instrument Mounting Bezel
01-125-5014
Motional Pickup Transducer
01-125-6148
Instrument Mounting Bezel
01-125-7335
Motional Pickup Transducer
2.630" overall length 1.850" overall width designed to be compatible with a type 2, 3000 psi hydraulic system per mil-h-5440; M40 to P275 deg f fluid temp rating; 85 psi operating pressure; 4 sets of windings; 8 volts rms, 1833 hertz, single phase excitation voltage; 250 ohms min input impedence; 500 ohms output impedence
01-125-8028
Motional Pickup Transducer
Used on aircraft model f-18.
01-125-8859
Motional Pickup Transducer
Used on aircraft model f-18.
01-126-0286
Metal Detecting And Tracing Set
Range 18" to 1 feet in depth, battery operated, frequency up to 480 khz, approx 5 vdc, with head set
01-126-0445
Instrument Mounting Bezel
3.250" overall length 3.250" overall width includes light shield bracket, 2 holes; 3 holes, 0.128 in. nom dia thru anodize surface treated
01-126-3414
Motional Pickup Transducer
3.000" overall length
01-127-1922
Motional Pickup Transducer
35.380" overall length operating temperature range minus 18.0 deg c to plus 70.0 deg c; output impedance 100 ohms; core 12.000 in.lg; coil formaterial high density, glass-filled polymer; housing material aisi 400 seriess tainless steel; lead wires 28 awg, stranded copper, polytetrafluoroethylene-insulated, 12.000 in.ln.lg
01-127-4786
Meter Movement
01-127-5864
Secondary Transf Calibration Set
Used on dla/gsa managed unable to id end item.
01-128-0185
Vehicle Chassis Sing Dynamometer
01-128-5659
Meter Register
01-128-9484
Motional Pickup Transducer
Used on misc electronic parts.
01-128-9705
Motional Pickup Transducer
Press range 8 hg differential
01-128-9787
Instrument Mounting Bezel
3.250" overall length 3.250" overall width anodize surface treated
01-129-3280
Motional Pickup Transducer
The difference between output voltages of individual elements within transducer shall not differ from each other by more than .050 vrms at any output position over the temperature range
01-129-4696
Meter Movement
01-129-7231
Meter Movement
01-129-7571
Motional Pickup Transducer
01-130-6739
Primary Referenc Calibration Set
Used on b-52g/cm. consists of a pressure gage, flowmeter,
01-131-5299
Instrument Mounting Bezel
Used on f16a acft. 3.250" overall length 3.250" overall width hole 0.135 in. dia, 0.250 in. nom dia cbore, 0.200 in. dp, 0.375-24unf-2b, 0.100 in. dp
01-133-6033
Motional Pickup Transducer
Used on flight set. 1.700" overall length 0.164-32 in.unc 2a thd; beryllium copper probe; excitation 8.0 vac at 1.833 khz; four wire leads 12.000 in.lg
01-133-8864
Instrument Mounting Bezel
4.062" overall length 4.062" overall width
01-133-9379
Indicator Housing
6.844" overall length
01-134-1361
Motional Pickup Transducer
20.580" overall length primary leads red
01-134-3027
Interferometer
01-134-5072
Motional Pickup Transducer
Used on position indicator. 7.875" overall length 6.625" overall width metal housing; 0.125 in.over all travel
Page: 32 ...