NSN 6685-01-462-7959 NIIN 014627959 — Digital Hygrothermometer

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6685-01-462-7959
6685014627959
Description:
HYGROTHERMOMETER,DIGITAL
NSN Assigned:
18-FEB-99
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6685-01-462-7959 Specification Set by the OEM (see RNCC code 3)

Overall Depth ABFY:

1.350in.

Overall Length ABHP:

7.000in. ⁓7-1/64"

Overall Width ABMK:

2.750in.

End Item Identification AGAV:

pacer special

Voltage Rating In Volts ASXH:

9.0 dc

Measurement Type BFHZ:

thermoelectrical circuit

Display Type BFQN:

liquid crystal

Display Digit Quantity BFQP:

4

Switch Type And Quantity BGJN:

8 push button

Case Type BHMC:

carrying case w/handle

Measurement Range BHMW:

-30.0/+85.0 deg celsius and -22.0/+185.0 deg fahrenheit and +0.0/+95.0 percent relative humidity

Part Name Assigned By Controlling Agency CXCY:

thermohyromoter; temperature/humidity/dew point indicator

Special Features FEAT:

temperature range -22 to +185 deg f, -30 to +85 deg c; temperature accuracy +/- 1.8 deg f (+/-1 deg c) ; humidity range 0 to 95% rh (NON-Condensing) ; humidity accuracy +/-2 percent from 0 to 60 percent rh; +/-3 percent from 61 to 95percent rh; average response time 3 seconds to move 60 percent of scale; calculated dew point range -20 to +120 deg f; -30 to +50 deg c; calculated dew point accuracy +/-2 deg c (+/-3 deg f) from 30 to 95 percent rh; one 9 volt battery; numeral heighth .9in.; stores 16 readings

Material MATT:

plastic

Special Test Features SPCL:

comes with one point nist traceable certification of calibration

Style Designator STYL:

hand held

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
TH300
Cage Code:
0P3J6
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
38844
FIIG:
A27600
Concept No.:
App. Key:
Q
Cond. Code:
1
Status:
A
STYLE DESIGNATOR HAND HELD style nsn 6685-01-462-7959

Definition Definition of approved item name (AIN): "HYGROTHERMOMETER,DIGITAL"

An instrument for measuring and indicating by digital display relative humidity and temperature of the surrounding atmosphere. Measurements are made by sensors generally mounted in a probe.

6685-01-462-7959 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
FHZ
SOS:
MMAC:
KR
MCC:
Source of Supply (SOS) FHZ

Oklahoma city air logistics center 3001 staff drive tinker afb, ok 73145-3303

Material Management (MMAC) KR

Miscellaneous aircraft support components

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.