NSN 6685-00-855-6525 NIIN 008556525 — Indicating Capillary Thermometer

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6685-00-855-6525
6685008556525
Description:
THERMOMETER,INDICATING,CAPILLARY
NSN Assigned:
29-SEP-67
DEMIL:
NO
Shelf Life:
N/A
UOM:
No qup EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6685-00-855-6525 Specification Set by the OEM (see RNCC code 3)

Case Diameter ABKJ:

2.280in.

Mounting Facility Screw Thread Series Designator AKEJ:

unf

Dial Diameter ASSP:

1.750in.

Scale Type ATEQ:

concentric dial

Scale Smallest Increment AWAG:

40.0 deg fahrenheit

Mounting Facility Type And Quantity AXHR:

1 stud and 1 bracket

Scale Inscription/background Color BGKZ:

white marking on black background, dial marked temp f

Case Type BHMC:

vaporproof

Actuating Medium BKCM:

ether

Bulb Quantity BKCT:

1

Bulb Type BKCW:

plain rigid

Bulb Connection Type BKCX:

union

Active Portion Length BKCY:

0.800in.

Active Portion Diameter BKCZ:

0.365in.

Indicator Connection Method BLQF:

flexible tube

Flexible Tube Length BLQG:

48.000in.

Mounting Thread Quantity CGGK:

32 per inch

Mounting Facility Nominal Screw Thread Diameter CRYY:

0.190in.

Scale Measurement Range CSYG:

+100.000/+220.000 deg fahrenheit

Bulb Overall Length CSYH:

1.430in.

Pointer/pen Type And Quantity CSYJ:

1 indicating single

Material MATT:

steel meter case

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
1513716
Cage Code:
7X677
RNCC:
C
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
9X
Part Number:
1513716
Cage Code:
70040
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
HD
Status:
A
MSDS:
SADC:
Part Number:
1513716
Cage Code:
72582
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
HD
Status:
A
MSDS:
SADC:
Part Number:
1513716
Cage Code:
24617
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
9Z
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
07419
FIIG:
A27600
Concept No.:
App. Key:
H
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "THERMOMETER,INDICATING,CAPILLARY"

A thermometer which employs a confined substance, whose measurable physical properties or one of them varies with a change in temperatrue and this energy transmitted into mechanical movement to indicate the temperature. For indoor/outdoor application, see thermometer, self-indicating, liquid in glass.

6685-00-855-6525 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
N35
SOS:
MMAC:
MCC:
Source of Supply (SOS) N35

Naval inventory control point mechanicsburg, pennsylvania 17055-0788

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.