NSN 6685-00-618-9542 NIIN 006189542 — Absolute Pressure Dial Indi Gage

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6685-00-618-9542
6685006189542
Description:
GAGE,ABSOLUTE PRESSURE,DIAL INDI
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6685-00-618-9542 Specification Set by the OEM (see RNCC code 3)

Overall Depth ABFY:

3.8125in.

Bolt Circle Diameter ABKG:

3.500in.

Mounting Hole Diameter ABTB:

0.138in.

Mounting Hole Quantity ABTJ:

3

Overall Diameter ADAV:

3.250in. ⁓3-1/4"

Case Material ADTV:

aluminum

Case Surface Treatment ADTY:

enamel, black

Graduation Unit ANBJ:

1.000in. of mercury and 2.000in. of mercury

Actuation Type APCM:

diaphragm

Adjustability APCS:

nonadjustable

Scale Range APSK:

+0.000/+10.000in. of mercury and +0.000/+200.000in. of mercury

Scale Name AQFZ:

pressure and pressure

Dial Size ARCH:

2.281 in. dia.; 1.610 in. dia.

Connection Quantity ASMM:

1

Pointer Color ASSS:

yellow fluorescent both pointers

Pointer Type ASST:

indicating and indicating

Scale Marking ASTW:

inches hg abs; in. absolute pressure

Scale Type ATEQ:

multiple

Scale Smallest Increment AWAG:

0.100in. of mercury and 10.000in. of mercury

Connection Type AWLS:

internal

Mounting Method AXGY:

flush panel

Scale Accuracy BGKS:

1 pct entire range both scales

Actuating Element Material BGKY:

beryllium copper

Scale Inscription/background Color BGKZ:

yellow fluorescent marking on black background

Connection Location BGRY:

back

Bezel Type BHMD:

SLIPS-On

Protective Crystal Material BHMF:

glass

Connection Size BHMG:

1/8 in. npt

Mounting Connection Location BHMH:

back

Connector Type Vent BHMK:

not provided

Material MATL:

aluminum

Material MATT:

aluminum

Surface Treatment SFTT:

paint crackle finish

Surface Treatment SURF:

finish, black, crackle

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
B08385-04-011
Cage Code:
89944
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
SE
Status:
A
MSDS:
SADC:
Part Number:
838K4-011
Cage Code:
89944
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
SE
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
07420
FIIG:
T179-B
Concept No.:
App. Key:
BA
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "GAGE,ABSOLUTE PRESSURE,DIAL INDI"

An instrument designed to measure pressure, and indicate in terms of pressure above vacuum (zero pressure) by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) without the necessity of correction or adjustment for barometric or atmospheric pressure. for items that do not have an internal pressure sensitive element see indicator, pressure.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
230.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6685-00-618-9542 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.