NSN 6680-01-505-3778 NIIN 015053778 — Flow Rate Indicating Meter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6680-01-505-3778
6680015053778
Description:
METER,FLOW RATE INDICATING
NSN Assigned:
05-MAR-03
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6680-01-505-3778 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

9.875in. ⁓9-7/8"

Media For Which Designed ACKL:

air

Inlet Connection Type ACQW:

threaded

End Item Identification AGAV:

panel tube assy; asds NON-Soc retail stock

Integral Relief Valve AHZU:

not included

Meter Type ANTH:

float

Design Type APGF:

glass

Unit Type APQB:

mounted

Scale Quantity APSJ:

1

Outlet Connection Type ARTH:

flange

Scale Marking ASTW:

standard cubic feet per minute

Scale Type ATEQ:

direct capacity reading

Float Quantity AWAE:

1

Tube Material AWGJ:

plastic

Mounting Method AXGY:

surface panel

Dial Scale Marking Range BHBY:

+1.0/+12.0

Outlet Connection Size BHCM:

1/2 inch npt (male)

Float Type BHSQ:

guided

Float Material BJDM:

steel, stainless

Guide Type BMHW:

solid rod

Integral Heat Source BNHN:

not included

Maximum Working Pressure BPHD:

150.0 pounds per square inch

Inlet Connection Size CPZD:

0.500 inch npt (male)

Metering Tube Quantity CPZF:

1

Dial Scale Reference Pointer CPZK:

not included

Float Quantity Per Tube CPZL:

1

Spinning Float CPZM:

not included

Integral Pulsation Dampener CPZN:

not included

Inlet Connection Position For Which Designed CPZP:

vertical

Outlet Connection Position For Which Designed CPZR:

vertical

Alarm Signal CPZT:

not included

Special Features FEAT:

max operating temp: 116 degrees celsius; (inavy) flowmeter

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
7326559 FIND 16
Cage Code:
53711
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
P-32471-05
Cage Code:
05668
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
38346
FIIG:
T134-T
Concept No.:
App. Key:
TA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "METER,FLOW RATE INDICATING"

An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes meter, fluid flow indicating, differential pressure; meter, fluid flow indicating, electromagnetic; and meter, fluid flow indicating, ultrasonic.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
05
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 05

Delicate instrument.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6680-01-505-3778 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.