NSN 6680-01-129-6465 NIIN 011296465 — Flow Rate Indicating Meter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6680-01-129-6465
6680011296465
Description:
METER,FLOW RATE INDICATING
NSN Assigned:
08-APR-82
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6680-01-129-6465 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

9.812in. ⁓9-13/16"

Media For Which Designed ACKL:

any acceptable

Inlet Connection Type ACQW:

threaded

End Item Identification AGAV:

howell laboratories inc, fuel storage release line

Integral Relief Valve AHZU:

not included

Meter Type ANTH:

float

Design Type APGF:

case

Unit Type APQB:

mounted

Scale Quantity APSJ:

1

Construction ARQS:

side plate

Outlet Connection Type ARTH:

threaded

Scale Type ATEQ:

direct capacity reading

Float Quantity AWAE:

1

Tube Material AWGJ:

glass

Mounting Method AXGY:

flush panel

Carrying Handle AXQG:

not included

Outlet Connection Size BHCM:

0.250 in. npt

Base BHJT:

not included

Float Type BHSQ:

free

Integral Heat Source BNHN:

not included

Maximum Working Pressure BPHD:

250.0 pounds per square inch

Inlet Connection Size CPZD:

0.250 in. npt

Metering Tube Quantity CPZF:

1

Dial Scale Reference Pointer CPZK:

not included

Spinning Float CPZM:

not included

Integral Pulsation Dampener CPZN:

not included

Inlet Connection Position For Which Designed CPZP:

horizontal

Inlet Connection Device Type CPZQ:

stationary

Outlet Connection Position For Which Designed CPZR:

horizontal

Outlet Connection Device Type CPZS:

stationary

Alarm Signal CPZT:

not included

End Item End items to which 6680-01-129-6465 is a component of

  • A8N AIR COMPRESSORS, HIGH PRESSURE
  • AGN L.P. COMPRESSORS
  • CHN LOW PRESSURE (LP) DRY AIR-DEHYDRATORS
  • EZN TICONDEROGA CLASS CG (47)
  • FBN SPRUANCE CLASS DD (963)
  • JFN OLIVER PERRY CLASS FFG
  • JKN WASP CLASS LHD
  • JPN SUPPLY CLASS AOE
  • JRN FMS - KNOX CLASS FF
  • W5N AUSTIN SHIP CLASS LPD-4 AMPHIBIOUS TRANSPORT DOCKS

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
1355V
Cage Code:
4ZW64
RNCC:
C
RNVC:
1
DAC:
E
RNAAC:
Status:
A
MSDS:
SADC:
9F
Part Number:
1355V SIZE 2
Cage Code:
4ZW64
RNCC:
C
RNVC:
1
DAC:
4
RNAAC:
Status:
A
MSDS:
SADC:
9F
Part Number:
4564BG502
Cage Code:
22501
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
1355V SIZE 2
Cage Code:
91556
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
1533EZ34
Cage Code:
91556
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
2-1355-V-2C-Z
Cage Code:
91556
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
1355V
Cage Code:
91556
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
38346
FIIG:
T134-T
Concept No.:
App. Key:
TA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "METER,FLOW RATE INDICATING"

An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes meter, fluid flow indicating, differential pressure; meter, fluid flow indicating, electromagnetic; and meter, fluid flow indicating, ultrasonic.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
1.6000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
05
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 05

Delicate instrument.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6680-01-129-6465 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.