NSN 6680-01-119-3932 NIIN 011193932 — Liquid Level Switch

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6680-01-119-3932
6680011193932
Description:
SWITCH,LIQUID LEVEL
NSN Assigned:
23-SEP-81
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6680-01-119-3932 Specification Set by the OEM (see RNCC code 3)

Power Cable Length ABJP:

48.000in.

Ac Voltage Rating ACYN:

120.0 volts

Frequency Rating ACZB:

60.0 hertz

Specific Equipment Accommodated AFJE:

liquid level control

Actuation Method AFLW:

buoyancy

Electrical Connection Type AGBD:

cable

Internal Battery Accommodation ALSF:

not included

Current Rating At Maximum Rated Voltage APGW:

5.0 amperes resistive load

Voltage Rating At Maximum Rated Current APGY:

120.0 volts

Float Quantity AWAE:

1

Operating Temp Rating AWTN:

-65.0 deg fahrenheit and 180.0 deg fahrenheit

Mounting Method AXGY:

thread

Mounting Position BBJX:

vertical

Maximum Current Rating BJKC:

5.0 amperes resistive load

Contact Arrangement BJKD:

spst, normally open, normally closed

Relay BJKG:

included

Float Effective Travel BJKN:

14.250in.

Mounting Dimensions BJKP:

mtd by one 1.250 NPT-11 1/2 plug

Tank Insertion Length BJKQ:

18.000in.

Phase FAAZ:

single

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
LS-46095
Cage Code:
04034
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
46095
Cage Code:
04034
RNCC:
3
RNVC:
1
DAC:
A
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
37187
FIIG:
T109-D
Concept No.:
1
App. Key:
DA
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "SWITCH,LIQUID LEVEL"

A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. Used in conjunction with pumps or valves to transfer liquid from one source to another. It may include a relay controlled by the switch element. Excludes transmitter, liquid quantity.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
7.4000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6680-01-119-3932 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.