Description:
METER,FLOW RATE INDICATING
NSN Assigned:
01-JAN-62
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Air Force

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6680-00-985-2303 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

24.625in. ⁓24-5/8"

Inlet Connection Type ACQW:

threaded

Dial Range AEWH:

+8.0/+100.0

Integral Relief Valve AHZU:

not included

Meter Type ANTH:

float

Design Type APGF:

case

Unit Type APQB:

mounted

Scale Quantity APSJ:

1

Construction ARQS:

inclosed w/sight window

Outlet Connection Type ARTH:

threaded

Float Quantity AWAE:

1

Tube Material AWGJ:

glass

Mounting Method AXGY:

direct line

Carrying Handle AXQG:

not included

Outlet Connection Size BHCM:

1.500 in. ips

Base BHJT:

not included

Float Type BHSQ:

free

Float Material BJDM:

steel, stainless

Integral Heat Source BNHN:

not included

Inlet Connection Size CPZD:

1.500 in. ips

Metering Tube Quantity CPZF:

1

Dial Scale Smallest Increment CPZJ:

1pct

Dial Scale Reference Pointer CPZK:

not included

Spinning Float CPZM:

not included

Integral Pulsation Dampener CPZN:

not included

Inlet Connection Position For Which Designed CPZP:

horizontal

Inlet Connection Device Type CPZQ:

stationary

Outlet Connection Position For Which Designed CPZR:

horizontal

Outlet Connection Device Type CPZS:

stationary

Alarm Signal CPZT:

not included

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
10A4655AZ
Cage Code:
22375
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
10A273515M64
Cage Code:
22375
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
38346
FIIG:
T134-T
Concept No.:
App. Key:
TA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "METER,FLOW RATE INDICATING"

An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes meter, fluid flow indicating, differential pressure; meter, fluid flow indicating, electromagnetic; and meter, fluid flow indicating, ultrasonic.

6680-00-985-2303 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
SX
MCC:
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

Material Management (MMAC) SX

Brac mmac for oc-alc

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.