NSN 6680-00-880-2458 NIIN 008802458 — Pressure Medical Gas A Regulator

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6680-00-880-2458
6680008802458
Description:
REGULATOR,PRESSURE,MEDICAL GAS A
NSN Assigned:
01-JAN-60
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6680-00-880-2458 Specification Set by the OEM (see RNCC code 3)

Body Material AAFZ:

aluminum alloy

Specific Gas For Which Designed AENF:

nitrogen

Regulation Type AEVN:

automatic

Stage Type AWNT:

single

Inlet Connection Nominal Pipe Size AWNW:

0.960in.

Inlet Adapter AWNX:

not included

Automatic Relief Valve AWNY:

included

Flowmeter AWNZ:

included

Cylinder Pressure Gage AWTF:

included

Inlet Connection End Style AWTG:

valve type

Err Default AWTK:

err default

Outlet Connection Nominal Pipe Size AWTL:

0.250in.

Cylinder Pressure Gage Range AWYD:

+0.0/+3000.0 pounds per square inch

Maximum Delivery Pressure AWYE:

140.0 pounds per square inch

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
5417N4A
Cage Code:
13669
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
5417N4A
Cage Code:
28968
RNCC:
5
RNVC:
9
DAC:
1
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
680A25
Cage Code:
28968
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
19229
FIIG:
T121-B
Concept No.:
App. Key:
BA
Cond. Code:
1
Status:
A
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458
INLET CONNECTION END STYLE VALVE TYPE style nsn 6680-00-880-2458

Definition Definition of approved item name (AIN): "REGULATOR,PRESSURE,MEDICAL GAS A"

A precision device designed to accept compressed medical gas from a cylinder and to deliver it to the administration apparatus at a safe pressure which is automatically maintained. It is usually furnished with a gage to indicate pressure in the cylinder and it may have a flowmeter to measure the volume of gas delivered.

6680-00-880-2458 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.