NSN:
6675-00-232-8923
6675002328923
Description:
TRANSIT
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6675-00-232-8923 Specification Set by the OEM (see RNCC code 3)

Carrying Case AFJU:

provided

Accessory Components And Quantity AKYD:

brush, lens cleaning 1; cap, objective lens 1; cover, waterproof 1; eyepiece, prismatic w/filters for solar observation 1; grease, lubricant instrument 1/4 oz tube 1; lamp, replacement 3; level vial, radioactive luminous compound treated 2; magnifier, hand, 30 mm lens dia 3-1/2 dia magnification 1; pin, adjusting 2; plumb bob, brass 10 oz w/cord and adjustor 1; screwdriver 1; sunshade 1; wrench, quantity as required for field stripping

Tripod AMYJ:

included

Illuminated Feature ANXY:

included

Leg Type BCFM:

fixed

Sighting Device Type BCGY:

telescope

Telescope Type BCTB:

erecting

Telescope Length BCTC:

10.000in.

Focusing Type BCTD:

external

Diameter Magnifying Power BCTF:

22.0

Telescope Level Vial BCTL:

included

Horizontal Circle Diameter BCWH:

6.250in.

Horizontal Circle Vernier Quantity BCWL:

2

Horizontal Circle Vernier Graduation Unit BCWM:

20.0 seconds

Horizontal Circle Minimum Graduation Unit BCWN:

15.0 minutes

Vertical Circle BCWP:

included

Vertical Circle Minimum Vernier Graduation Unit BCWQ:

1.0 minutes

Vertical Circle Minimum Graduation Unit BCWR:

30.0 minutes

Vertical Circle Stadia Arc Graduation BCWS:

not included

Compass BDCJ:

included

Reference Number Differentiating Characteristics ZZZY:

bcwm

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
132-20
Cage Code:
26612
RNCC:
3
RNVC:
1
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
18489
FIIG:
T144-M
Concept No.:
App. Key:
MD
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "TRANSIT"

An instrument having two coaxial centers, one inside the other. A telescope is attached to the inner center and mounted in such a manner that it may be rotated in vertical or horizontal arcs. The outer center carries the horizontal scale. The telescope and horizontal circular scale may rotate about the same axis, independent of each other, or integrally, as a single unit. The scales are read visually by means of verniers. The instrument is usually leveled by means of four leveling screws. It is used for measuring horizontal, or horizontal and vertical angles. Excludes transit, pocket.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
12.5 X 11.5 X 18.5
Paclk Weight:
28.0000lbs
Item Weight:
25.0000lbs
Item Dim:
010500950165
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6675-00-232-8923 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
Y
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) Y

Indicates information is in the hazardous materials information resource system (hmirs).

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.