Hazard-detecting Instruments And Apparatus FSG 66 — FSC 6665

NSN
NIIN
Name
Details
01-509-4251
Biological Agen Detection System
Used on aac248 248. drawing item name: joint point, trailer mounted, XM102 system, jbpds 5the item consist of: 30295-1110 (qty.1) x 30295-1111 (qty.1) x 30295-1215-1 (qty.1) x 30295-1260-1 (qty.1) x 30295-1270 (qty.1) x 30295-1975 (qty.1) x 30295-1980 (qty.1) x 30295-1983 (qty.1) x 30295-1604 (qty.1) x 30295-3025 (qty.1) x 30295-3100-1 (qty.1) x 30295-3150 (qty.1) x 20004303-001 (qty.1) x 4-74423-od (qty.1) x 30295-1402 (qty.1) x 30295-1404 (qty.1) x 30295-1613-004 (qty.1) x 30295-3030 (qty.1) x 30295-3033 (qty.1) x 30295-3034 (qty.1) x 30295-3035 (qty.1) x 30295-3036 (qty.1) x 30295-3038 (qty.1) x 30295-3040 (schematic diagram, trailer) x 30295-3041 (qty.1) x 30295-3042 (qty.1) x 30295-3043 (qty.1) x 30295-3044 (qty.1) x 30295-3045 (qty.1) x 30295-3047 (qty.1) x 8140b, cage 0A4Z6 (qty.10ft) x 81200b, cage 0A4Z6 (qty.15ft) x 8142n, cage 0A4Z6 (qty.20ft) // nha: 30295-4000
01-509-4866
Chemical Agent Sampling Kit
Sampling chemical-biological kit highly effecient field sampling kit; allows collection of potentially toxic
01-509-9540
Air Sampler Kit
Liquid sample collector for outdoor use-bio-aerosol collector ea
01-511-2853
Gas Detector
01-511-4002
Radiacmeter
8.750" overall length 4.380" overall width
01-511-4666
Sampling And Analyzing Kit Case
Carrying case for gilibrator 2 flow rate meter
01-511-4783
Gas Detector
Used on AGM-56. three 3.0mmdia mounting holes on a 34.4 mm bolt circle
01-512-0723
Gas Detector
Used on multirae plus (pgm-50) gas monitor.
01-512-0729
Gas Indicators A Calibration Kit
Used on multirae plus (pgm-50) gas monitor. four-gas mix in a 34l cylinder; calibration regulator (male)
01-512-1310
Gas Detector
Used on multirae plus (pgm-50) gas monitor.
01-512-1351
Biological Agen Detection System
01-512-4696
Hydrogen Sulfide Detector Tube
10 per pkg.; to detect hydrogen sulfide
01-512-4724
Gas Indicator Tube
Used on 6665-01-508-3257 kit,civil defense simultest. tube hydrazine detector 0.01-6ppm 10s hydrazine detector tube used in conjunction with nsn 6665-01-508-3257 hazmat detection kit; standard range of measurement at 20 deg c, 1013 hectopascals: 0.3 to 5 ppm , measurement time: 5 min; standard range of measurement (20 deg c, 1013 hpa) : 0.01 to 0.25 ppm, measurement time: 20 min; package of 10
01-513-9475
Mine Probe
01-514-1790
Roentgen Rate Meter
Pressurized ur ion chamber survery meter, battery operated, lcd display, tripod mount, auto-ranging
01-514-1835
Chemical Agent Analyzing Kit
Chemical identification system with drager pump chemical analysis system that will allow qualify
01-514-6895
Gas Detector
Used on residual spare. 1.750" overall length 1.125" overall width
01-514-7058
Gas Detector
01-514-9569
Gas Detector
11.300" overall length 4.100" overall width uses "tape cartridge" r/n 2740-1020, with approximately 1000 samples per tape. 6 v sealed lead calcium battery pack, audible alarm for chemical detection
01-515-0930
Gas Detector
8.200" overall length 3.000" overall width 4.8 nimh battery, alkaline battery holder supplied. accuracy less than 2000 ppm porm 2 ppm, greater than 2000 ppm porm 20 pct. range is 0 to 10, 000 ppm. eight character display, alarm 90 db buzzer
01-515-1748
Gas Detector
4.500" overall length 3.000" overall width 2 line, 16 digit display; 95 db
01-515-2178
Gas Detector
4.750" overall length 2.750" overall width
01-515-2182
Gas Detector
4.100" overall length 2.700" overall width
01-515-3895
Air Sampler Kit
Aircon-2 dc-programmable high volume air sampler mflow range:2-30 lvp; constant flow: 2-30 lpm at pressures up to 7 psi; run time: 8 hr min.; operating temp: -4 to 113 deg f; humidity range: 0-95 percent rh, non-condensing; electronic pressure display; full function timing program; instant-fault function; programmable memory (up to 3 custom programs) ; keypad: accept, prog, time/press, run/hold; indicatiors: lld display, external rotometer, instant fault, low battery; 4.3" w x 0.3 h x 7.5 d; 12vdc at 3.4 amp
01-515-5498
Gas Detector
01-515-5502
Gas Detector
01-515-6752
Gas Detector
Used on kit,gas free engineer. tube box, hydrogen flouride 0.5/a, 0.5-90 ppm material is hydrogen flouride 0.5/a: standard measuring range is 0.5-15 ppm/ 10-90 ppm: standard deviation is 20-30%; color change is blue violet to yellow; ambient operating conditions: temperature 10-40 c; absolute humidity is 30-80%: unit of issue is box (10) tubes in box
01-515-7777
Radiac Detector
Chamber overview-roentgens rate resolution 0.1 mr/hr; max 1.7 kr/hr; dose resolution 0.01 ur; max 2.3 kr; rate specifications 0.1 mr/hr-1.7 r/hr; 1ugy/hr-15 gy/hr; exposure specifications 0.01 ur-2.3 kr; 0.1 ngy-20 gy; calibration accuracy porm 4 pct using x-rays at 150 kvp
01-515-7778
Radiac Detecting Element
Rate resolution 0.01 mr/hr; max 65 r/hr; dose resolution 0.1 ur; max 230 r; rate specifications 0.1 mr/hr-65 r/hr; 0.1 ugy/hr-575 mgy/hr; exposure specs 1 nr-230 r; 0.01 ngy-2 gy; calibration accuracy porm 4 pct using x-rays at 150 kvp
01-515-7846
Radiac Set
Dfunctions auto zero; dose rate; max dose rate; dose; auto dose; pulsed, cine; lcd display test lcd display verification; battery test checks battery voltage; chamber voltage test checks bias voltage
01-515-7848
Radiac Set Subassembly
01-515-7849
Radiac Set Subassembly
01-515-7850
Radiac Set Case
01-515-7933
Monitor Chemical A Case Assembly
Used on screamer monitor;vertical launching system,mk-41.
01-515-8104
Air Sampling Pump
Skc airchek 2000, progrmmable, single pump kit with AC2000 pump, ni-cad battery, 230v single station charger
01-515-8343
Ambient Air Collector Kit
Used on used with jbpds, dry filter unit (dfu) and hand held assay panel.
01-516-3774
Detector-cooler Assembly
Used on pantera targeting pod. converts midwave infrared radiation into digital pxel data that is transmitted to processing electronics via a hot link; it contains the focal plane array in a dewer, fpa interface electronics, cooler, cooler controller electronics
01-516-3788
Mechanical Optical Assembly
Used on pantera targeting pod. provides focus correction for the lst, lrr, cid
01-517-7153
Chemical Agent Detector Kit
Pins-2 chemcial assay system pins-2 portable isotopic neutron-spectroscopy chemical assay system includes detector, digidart mca with usb connection, lap top computer, pins-2 software, support table, shield assembly, safety signs, tools, 30-liter storaage dewar, shipping case; neutron source is not included with the system
01-517-8296
Gas Detector
01-517-9389
Radiac Detector
Used on radiac program.
01-518-2097
Gas Detector
Tests for water vapor; 5.0 to 160 mg/M3 range
01-518-2098
Gas Detector
Tests for nitrogen dioxide; 0.2 to 6.0 ppm range
01-518-4407
Air Sampler Kit
Air sampler high accuracy; microprocessor based; battery-backed; data memory; lcd displays total volume, flow rate,
01-518-5451
Mine Detector Boom
1.500 feet overall length MK105 mod 4, magnetic minesweeping system pal; MK105 mod 4, wing assembly; navy: cylinder, boom lock
01-518-5512
Chemical Agent Detect Refill Kit
CO2 absorbent material 1 pint
01-518-6113
Radioactive Test Sample
85.0mm overall length radioactive material includes am-241
01-518-6118
Air Sampling Pump
5.100" overall length 4.700" overall width
01-518-6456
Radiac Set Case
Used on radiac program.
01-518-6468
Radiac Set
Used on 9999 ael an/pdq-4, radiac set; items with nuclear applications; an/pdq-4 radiac set.
Page: 27 ...