NSN 6640-01-236-3946 NIIN 012363946 — Laboratory Syringe

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6640-01-236-3946
6640012363946
Description:
SYRINGE,LABORATORY
NSN Assigned:
17-JUL-86
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Air Force, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6640-01-236-3946 Specification Set by the OEM (see RNCC code 3)

Capacity AXQD:

250.0 microliters

Barrel Glass Type BZPT:

borosilicate

Part Name Assigned By Controlling Agency CXCY:

syringe laboratory borosilicate glass barrel plunger ss shaft

Special Features FEAT:

syringe, stainless steel shaft, aluminum knob; ctfe plastic seal; 30 millionths of an in. clearance inside barrel; gastight; 2 scale: ml range 0-.25 in. single increments, ul range 0-250 in 25 ul increments; etched markings; metal luer lock w/ctfe plastic lower taper; CHROME-Plated brass outside, fluropolymer inside of specially made tip, w/dual exists (1 male, 1 female) , both threaded; sideport; for use w/tdx fluroesence polarization immunoanalyzer

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
9520-13
Cage Code:
33110
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
41980
FIIG:
T133-B
Concept No.:
App. Key:
BS
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "SYRINGE,LABORATORY"

A device consisting of a barrel with a piston or a plunger. May be supplemented with a needle or a delivery orifice on the distal end. May be specially designed. Used to deliver, transfer and/or store gases and fluids in a wide variety of applications, such as gas and liquid chromatography, handling of corrosive gases or liquids and transfer of radioactive and other dangerous gases or liquids. Not intended for injection or use on patients.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6640-01-236-3946 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.