NSN 6640-00-551-9364 NIIN 005519364 — Utility Laboratory Clamp

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6640-00-551-9364
6640005519364
Description:
CLAMP,UTILITY,LABORATORY
NSN Assigned:
01-JAN-61
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6640-00-551-9364 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

8.000in. ⁓8-1/64"

Sleeve Material AFTB:

asbestos

Construction ARQS:

round

Jaw Type ASYY:

single

Jaw Arms Adjustment Method BNGF:

single nut

Maximum Clamping Diameter BNGG:

1.500in.

Swivel Jaw BNGH:

not provided

Integral Attachment Provision BNGJ:

not provided

Material MATL:

aluminum alloy, QQ-A-591, alloy A380 and zinc alloy, QQ-Z-363, comp a

Material MATT:

aluminum alloy A380.0 and zinc alloy uns Z33520

Surface Treatment SURF:

nickel plated

Nondefinitive Spec/std Data ZZZT:

1 composition and 4 type and a size and ii composition

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
MS36012-2
Cage Code:
96906
RNCC:
2
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
GGC411C0MP0SITI0N10R2TYPE4SIZEA
Cage Code:
81348
RNCC:
4
RNVC:
1
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
5-732
Cage Code:
22527
RNCC:
5
RNVC:
1
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
21996
FIIG:
T269-R
Concept No.:
App. Key:
RA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "CLAMP,UTILITY,LABORATORY"

A device consisting of one or two sets of spring loaded jaws, and either an extension rod, for attaching to support rod by means of a laboratory support rod clamp, or other means for direct attachment to a supporting rod or shelf. Excludes clamp, test tube; clamp, tubing; and clamp, laboratory support rod.

6640-00-551-9364 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.