01-512-4953
Physical Prop Reference Standard
Used on f/a-22 raptor. 7.000" overall length 4.000" overall width reference standard, physical properties consists of a composit plate with 20 holes from 5/32" to 3/4" in 1/32 increments; 9 notches
01-512-7109
Particle Size Analyzer
Used on models pc8000a, abs2, 4000.
01-512-9276
Physical Prop Reference Standard
Used on f-22 raptor. ref std, ndi-metal 3 cases with lids consisting of references
01-512-9277
Physical Prop Reference Standard
Used on f/a-22 raptor. reference standards, physical properties
01-513-0290
Ultrasonic Test Set
01-513-1602
Strain Gage
6.35mm long; 120.0 ohms resistance, 0.4 porm tolerance
01-513-4181
Densitometer
Used on boeing 747 aircraft
01-513-4182
Densitometer
Used on boeing 747 aircraft
01-515-5714
Eddy Current Probe
01-515-5715
Eddy Current Probe
01-515-7038
Eddy Current Probe
Used on pwa500576.
01-515-7039
Eddy Current Probe
Used on pwa500576.
01-516-0676
Eddy Current Probe
Ra scanner probe expanding tip; probe expansion range 0.218 to 0.250 inch; working length 1.100 inch
01-516-0744
Particle Counter
Used on t45 aircraft contract supported. particle counter fl
01-516-1511
Electrical-electron Plug-in Unit
01-516-2142
Metal Flaw Electronic Detector
Height 11.150", width 6.550", thick 2.600", battery 12v, full/half wave pos or neg rectification, dual gate w/echo to echo measurements
01-516-2872
Supersonic Test Transducer
Used on nek1008 f-16 tension strut kit. built-in radius; spring loaded
01-516-2955
Eddy Current Probe
Expansion range .250-.281 in.; working length: 1.1 in.; plastic tips; 500khz - 3mhz relfection differential coil
01-516-2956
Eddy Current Probe
Expansion range .500-.562 in.; working length: 1.5 in.; plastic tips; 500khz - 3mhz relfection differential coil
01-516-2957
Eddy Current Probe
Expansion range .687-.750 in.; working length: 1.5 in.; plastic tips; 500khz - 3mhz relfection differential coil
01-516-2958
Eddy Current Probe
Expansion range .562-.625 in.; working length: 1.5 in.; plastic tips; 500khz - 3mhz relfection differential coil
01-516-2959
Eddy Current Probe
Expansion range .625-.687 in.; working length: 1.5 in.; plastic tips; 500khz - 3mhz relfection differential coil
01-516-6737
Eddy Current Probe
01-516-7406
Metal Flaw Electronic Detector
01-517-1987
Metal Flaw Electronic Detector
Frequency range 0, 5 to 15 megahertz; measures 9.6 in. wide, 7.7 in. high, 2.1 in. deep
01-518-2193
Eddy Current Probe Set
Name assigned by manufacturer set of six conductivity samples
01-518-4333
Metal Flaw Electronic Detector
Used on t-6a training aircraft. kit contains p/n 220520 model ed-520me eddy current instrument with accessories including aluminum 3 slot test block, general purpose probe (222296) , probe cable (210826) ,
01-518-4365
Eddy Current Probe
01-518-5118
Eddy Current Probe
01-519-0960
Probe Holder
Used on gage,profile 5220-01-142-3187. 1.932" overall length 0.375" overall width probe, assembley consist of pin brazed to probe. placed on top edge 4th stage turbine blades F100-pw-100/200/220/220e engines setting in a checking fixture. determine need to repair blades
01-519-2485
Portabl Magnetic Inspection Unit
Dry or wet method inspection, legs adjust 3 to 12", on/off switches, ac/dc switch, effective polished coated surface, operates all positions, dc field intensifying potentiometer
01-519-2487
Spring Resiliency Tester
Accuracy porm 0.5 pct full scale; peak capture; tare ring, storage case
01-519-2819
Industrial X-ray Equipment
Used on bomb disposal robot. 150p film processor
01-519-4196
Ultrasonic Test Transducer
Used on used to test r/n 9103m56p08, nsn 2840-00-242-1041 rotor compressor of the t38 engine. hconsists of the following: r/n 389-35-681 utrasonic probe; r/n 118-140-012 probe cable, nsn 6635-01-172-9280; r/n 9740M54P01 reference standard; r/n storage case 20in x 16in x 8in; total weight 10 lbs
01-519-4298
Supersonic Test Transducer
Seven pin; 165 khz in 0.500 in. diameter case; type/model number: s-pr-4
01-519-4557
Strain Gage
Used on eddy current equipment. gage standard assembly
01-519-4560
Ultrasonic Test Transducer
Used on cp140 flight deck simulator and cockpit procedures trainer. 7.625" overall length 4.500" overall width ptc self-resetting fuse; 50 khz ultrasound
01-519-5279
Radiographic Film
M100 indx paper
01-519-6093
Eddy Current Probe
Reference standard aluminum
01-519-6201
Metal Flaw Electronic Detector
Used on eddy current equipment
01-519-6208
Probe Holder
Used on f100-pw-100, f100-pw-200, f100-pw-220, f100-pw-220e and f100-pw-229 acft engines. semi-automated eddy current inspection
01-519-6213
Eddy Current Probe
Used on f100-pw-100, f100-pw-200, f100-pw-220, f100-pw-220e and f100-pw-229 acft engines. manual air seal inspection
01-519-6214
Eddy Current Probe
Used on f100-pw-100, f100-pw-200, f100-pw-220, f100-pw-220e and f100-pw-229 acft engines.
01-519-6215
Eddy Current Probe
Used on f100-pw-100, f100-pw-200, f100-pw-220, f100-pw-220e and f100-pw-229 acft engines. radius; semi-auto/manual; 1st stage turbine disk blade set
01-519-6235
Physical Prop Reference Standard
Used on moisture/density gauge, humboldt scientific, inc., model hs-5001ez. small white reference block
01-519-7071
Eddy Current Probe
6.000" overall length tip diameter - 5/16 inch; ferrite shielded low frequency right angle probe; 1-20 khz differential (bridge) coil; 0.375 inch drop
01-519-8012
Particle Counter
Used on LGM30. 26.000" overall length 14.000" overall width 50.000 watts or 60.000 watts wattage rating 110.0 ac or 120.0 ac voltage in volts and current type hipress gas probe operating pressure 40 to 150 psig. sizing sensativity available 0.1 micron with flow rate 0.1 scfm. housed in cylindrical pressure vessel. power disabled if gas leaks to environment or into vessel.0xygen/hydrogen compatibleefficienty >50% at 0.14 microns. calibration material traceable nist
01-519-8198
Torque Wrench Tester
Used on calibration standards. smanufacturer nomenclature: torque motorized calibration system; system consist of monitor, motorized loader, roller cabinet
01-519-9216
Surface Coating Tester
27.000" overall length 16.000" overall width portable"stick type"detector unpackaged unit weight is 35.000
01-520-5047
Metal Flaw Electronic Detector