01-462-4438
Cable Tensiometer Tester
01-462-6003
Torque Wrench Tester
Used on c-17 acft. range 100-2000 lb/ft; torque values in either n-m or lb-ft; accuracy of 0.25% full scale; power source of 100-130 vac at 50/60 hz; the tester consists of a calibration stand
01-462-6824
Radiographic Processing Machine
47.000" overall length 27.000" overall width tank capacities: developer 6.3 gal, fixer 5.3 gal, rinse water 5.3 gal; water consumption 6l/min with 0.750 in connection; replenisher rates: developer 900ml/min, fixer 1200ml/min; power consumption 3300 w max; munber of films developed per hour () 375 for 3.54 in by 4.72 in, 40 for 14in by 1n; weight with full tanks 550 lbs; infra-red film dryer
01-462-7532
Supersonic Test Transducer
Used on nimitz class cvn. iultrasonic inspection system; pressure
01-462-9860
Physical Prop Reference Standard
01-463-0793
Ultrasonic Test Set
6mfg name transducer set ultrasonic; kit includes transducer assy left 2251M33P01, transducer assy right 2251M33P02, tuning adapter 2251M34P01, reference left 2251M35P01, reference standard right 2251M35P02, coaxial cables c-012, storage case 14112
01-463-0882
Ultrasonic Test Transducer
Back transfer 5/13/08
01-463-0883
Balancing Way Stand
16.000" overall length 14.000" overall width materiel, aluminum alloy
01-463-3214
Eddy Current Probe Set
Steering crank nose landing gear kit; kit content includes manual hole probe, rotary probe, reference standard, cable
01-464-2249
Particle Size Analyzer
Flow rate: 1 cubic foot per minute; zero counts: < 1 count in 60 minutes; coincidence loss: < 5 percent at 200.000 particles/ft cubed; display: led; light source: laser diode; sample time: 1 second to 24 hours; sample hold time: 1 second to 24 hours; outputs: RS232/RS485; data storage; 400 samples; built-in printer; channels: 5; sensitivity: 0.3 or 0.5um; size of channels: 0.3, 0.5, 1.0, 5.0,
01-464-2278
Physical Prop Reference Standard
Used on b-2 aircraft. 13.000" overall length 10.000" overall width consist of 20 to 1 scarf containing simulated defects 0.5 inch in diameter
01-464-3550
Eddy Current Probe
3.000" overall length 2.000" overall width
01-464-3712
Eddy Current Probe
Used on 6635013784011, fscm 29192, detector, metal flaw, electronic.
01-465-1383
Eddy Current Probe
Used on 663501378011. the probe is used in conjunction with manual
01-465-1802
Spring Resiliency Tester
Test stand, elec load cell, dial indicator
01-465-2021
Eddy Current Probe
Used on 6635013784011. the probe is used in conjunction with manual
01-465-2027
Eddy Current Probe
Used on 6635013784011. rthe probe is used in conjunction with the manual
01-465-2301
Eddy Current Probe
Used on 6635013784011. the probe is used in conjunction with the manual
01-465-2897
Eddy Current Probe
Used on detector,metal,flaw,electronic - 6635013784011. sthe probe is used in conjunction with the manual
01-465-3141
Eddy Current Probe
Qbroach slot of the first
01-465-3153
Eddy Current Probe
Rbroach slot of the first
01-465-3157
Eddy Current Probe
Rbroach slot of the first
01-465-3163
Eddy Current Probe
Rbroach slot of the first
01-465-3164
Eddy Current Probe
Rbroach slot of the first
01-465-3166
Eddy Current Probe
Rbroach slot of the first
01-465-3173
Eddy Current Probe
Broach slot of the first
01-465-3174
Eddy Current Probe
Broach slot of the first
01-465-3176
Eddy Current Probe
Rbroach slot of the first
01-465-9205
Eddy Current Probe
Used on c-17 aircraft. 3.000" overall length 0.500" overall width produces frequencies of 1-5 mhz operates in 1-3 mhz range. contains a female microdot connector (microtech PN4-50-4 or equal)
01-466-0981
Eddy Current Probe
Used on cass otps 8g.
01-466-1496
Metal Flaw Electronic Detector
Used on eddy current tester. mfr name fixture, calibration
01-466-1518
Eddy Current Probe Set
Mfr name inspection kit, eddy current-hpt spacer, aft flange; used withp/n 1C7179G01 inspection kit, eddy current hi speed-common hardware
01-466-2082
Metal Flaw Electronic Detector
Used on an/avr-2a(v)1.
01-466-2642
Eddy Current Probe Set
Used on stg 2 fan disk of tf39 engine. tool set, eddy current inspection stg 2 fan disk
01-466-7645
X-ray Tube
Used on xr200 head assembly. 8.000" overall length
01-467-1389
Eddy Current Probe
Used on 1680004182796.
01-467-1626
Station Magnetic Inspection Unit
Max contact head opening 52" PORM2":wet horizontal machine: output dc 6000 amps with max 6pct ripple, ac 5000 digital ammeter displays ac rms amps, or dc amps at coil/contacts:current continuously variable:headstock pressurefoot switch activated:input air pressure 80-90psi
01-467-4756
Physical Pr Test Set Subassembly
Is a single sample table abraser; control panel c/o various control keys, digital display for the led readouts
01-467-5967
Eddy Current Probe Set
Used on tf39 engine hpt front rotor shaftbolt holes. identify flaws which produce indication greater than 2.5 major divisions on the crt
01-467-6223
Eddy Current Probe Set
Mfr name eddy current tool; used in conjunction with 1C7179G01 inspection kit, eddy current hi-speed common hardware to perform eddy current inspection of the tf-39 lpt rotor front shafts
01-467-6224
Eddy Current Probe Set
Mfr name eddy current tool; used in conjunction with 1C7179G01 inspection kit: eddy current hi-speed common hard ware to perform eddy current inspection of tf-39 hpt stg 1 disk rim boltholes
01-467-6225
Eddy Current Probe Set
Mfr name eddy current tool; used in conjunction with 1C7179G01 inspection kit, eddy current hi-speed common hardware to perform eddy current inspection of the tf-39 hpt stg 2 disk bolt holes
01-467-6413
Eddy Current Probe
Has a probe witness line
01-467-6791
Physical Pr Test Set Subassembly
Used on f-100-200 eng 21f aircraft freedon fighter f5 fpz.
01-467-8365
Eddy Current Probe Set
Used on tf39 engine hpt rotor rear shaft bolt holes. identify flaws which produce indication greater than 2.5 major divisions on the crt
01-467-9208
Ultrasonic Test Transducer
01-468-3926
Eddy Current Probe Set
Mfr name probe kit, eddy current-bolt hole, manual; 11 probe sizes 1/8"5/32", 3/16-1/4", 1/4-5/16", 5/16-3/8", 3/8-7/16", 7/16-1/2", 1/2-5/8", 5/8-3/4", 3/4-7/8", 7/8-1"; used in conjuntion with eddyscope p/n NORTEC19eii; also used in conjunction with a titanium reference standard used to calibrateeddy scope
01-468-5168
Eddy Current Probe Set
Mfr name probe kit, eddy current-bolt hole, automatic; 9 probes sizes 1/8", 5/32", 3/16-1/4", 1/4-5/16", 5/16-3/8", 3/8-7/16", 7/16-1/2", 1/2-5/8", 5/8-3/4"; used in conjunction with eddy scope p/n NORTEC19eii; also used in conjuntion with a titanium reference standard used to calibrate eddyscope
01-468-5701
Ultrasonic Test Transducer
Used on test set,ultrasonic,stavely pn9622062,nsn 6635013623327. 2.000" overall length 1.000" overall width mfg name pitch catch, probe:test up to 7 plies composites to detect 3/4inch dia flaw.connector-fisher pn FD104A56-130
01-468-8045
Industrial X-ray Equipment
190mm high x 115mm wide x 317.5mm long; 14.4 v removable, rechargeable nicad battery; 4000 pulses per charge; 25 pulses per sec ; 60 nanoseconds pulse length; 3000 max pulses per hour; 3mr per 100 pulses radiation leakage measureed 2in. from behind the unit; lcd can be set 1-99 pulses; 3mm source size; 15 or 60 sec time delay; 150kv photon energy