Physical Properties Testing And Inspection FSG 66 — FSC 6635

NSN
NIIN
Name
Details
01-360-6804
Supersonic Test Transducer
01-360-8285
Probe Holder
01-360-8314
Eddy Current Probe Set
01-361-1915
Particle Size Analyzer
01-361-2510
Eddy Current Probe
Used on detector metal flaw. 7.000" overall length tip .125 in.; 90 deg; mitered; 200 kilohertz frequency; .500 in. drop
01-361-5813
Metal Flaw Electronic Detector
Used on special aircraft and engine tool and se parts. eddy current flaw detector is compact self contained lightweight instrument for locating cracks
01-361-7429
Physical Prop Reference Standard
01-362-3327
Ultrasonic Test Set
Freq rng 500 hz to 1 mhz; gain rng 0 to 50 db; oper voltage 85-265 vac, 50-400 hz or 110-365 vdc; oper temp -10 to 131 deg f; storage temp -60 to 160 deg f
01-362-9184
Station Magnetic Inspection Unit
C/o control panel, headstock, instrument panel; grille; hose; coil; tailstock; rail; base frame
01-363-4773
Dial Indicating Tensiometer
Used on ohio class ssn (trident) ship.
01-363-4781
Densitometer
Used on emory s. land class as. 15.000" overall length 10.250" overall width
01-363-6674
Ultrasonic Test Set
3nain inspection system, ultrasonic, portable; ac & dc currents; 115.0-230.0, 50-60 hz; single phase; o.5 amps; 18.000 in. l, 12.000 in. w, 8.000 in. h; c/o ultrasonic instrument, 2 batteries, bbattery charger/eliminator w/padded corrosion resistant carrying case; sinusoidal or square wave; pulse width range 30-1000 ns; 300 v pulse; 0.5-20 mhz freq range; displays fullwave, filtered, halfwave porm rf; timebase 1-1200 msec min; digital analog signal & storagefor disk recorders; bnc connector, ttl compatible
01-364-0641
Eddy Current Probe
01-364-0642
Eddy Current Probe
01-364-0643
Eddy Current Probe
01-364-0674
Ultrasonic Test Transducer
01-364-5526
Metal Flaw Electronic Detector
Freq range F1: 100hz-3mhz. F2: 1/2, 1/4, 1/8 or 1/16 of F1; 5 in. digital storage; rs-170 compatible; sidebashows current instrument settings; lcdreadout, 2 lines of 16 char ea; sweep:0.005-4.0 sec/div, variable or externally triggered; alarms avail in 5 modeson impedance plane display; differential, absolute, reflection probes; stores up to 100 setups, 20 data storage locations; tape out avail; video output; rs-232 compatible; 12 vdc, gelled leadacid battery (8-hr) ; incl battery charger (120-240 vac, 50/60 hz) ; 5.500 in.h; 12.000 in. w; 15 in. dp; chassis modular aluminum w/polyurethane bumpers
01-364-6295
Eddy Current Probe Set
Phase 100 hz to 4 khz
01-364-6296
Eddy Current Probe Set
Phase 100 hz to 3 khz
01-364-6309
Material Hardness Tester
01-364-7564
Eddy Current Probe
01-364-7565
Eddy Current Probe
01-364-7566
Eddy Current Probe
01-364-7567
Eddy Current Probe
01-364-7568
Eddy Current Probe
01-364-8180
Eddy Current Probe
01-364-8192
Metal Flaw Electronic Detector
01-365-7129
Radiographic Ind X-ray Apparatus
Used on 6635-01-344-6403.
01-365-7619
Eddy Current Probe
1.000" overall length
01-365-9237
Ultrasonic Test Transducer
Used on c-5 aircraft. gamma
01-365-9535
Eddy Current Probe Set
Used on f100-pw-100,200,engine.
01-366-4017
Eddy Current Probe
Used on metal flaw detector 6635-01-316-5498. 5.800" overall length 1.900" overall width
01-366-5158
X-ray Apparatus Transformer
01-366-5746
Dial Indicating Tensiometer
Capacity 50, 000 lbs.; operating temp -4 deg to 140 deg f; digital display 4 pos. 1 in. high
01-366-6791
Station Magnetic Inspection Unit
01-366-6948
Dynamic-static Balancing Machine
01-366-9654
Metal Flaw Electronic Detector
Explosive ordnance disposal tools/equip
01-367-2187
Portabl Magnetic Inspection Unit
0.750" overall length 0.750" overall width miniature shim for small areas of test part; four circular flaws with a cross in the center of each; circle diameter
01-367-2188
Portabl Magnetic Inspection Unit
0.750" overall length 0.750" overall width steel; for more quantitative work; three evenly spaced concentric circular flaws of varying depth, 0.0004 in., 0.0006 in.,
01-367-2189
Portabl Magnetic Inspection Unit
Used on accessory; standard qqi, flaw depth of 30% of shim thickness,.002" thick;self adhesive.. 0.075" overall length 0.075" overall width navy:qqi flaw shim steel; for basic work; satisfies most needs because its circular crossed bar flaw configuration is suitable for longitudinal
01-367-2934
Eddy Current Probe Set
Used on acft model v-22.
01-367-2982
Surface Finish Contact Analyzer
Used on aircraft model h-60. dimensions: 10.000 in. lg., 5.000 in. w., 4.000 in. h.; unit is battery operated by 6 silverbatt stdrd batteries, when battery has a min of 10, 000 operations "bat" appears on the low indicator
01-368-8341
X-ray Film Processing Unit
3.666 feet overall width continuous roller transport system; 3 cycle speeds: short-8 1/2 min; long-12 1/2 min; variable speed; tanks: developer 3.8 gal, fixer 2.4 gal, washwater 2.7 gal incl in 1 tank; automatic temp control via heat exchanger
01-369-6638
Portabl Magnetic Inspection Unit
105-125 vac; 8 ft, 3 conductor power plug
01-370-2621
Test Sieve
Used on b1b oas serd 73u. tube diameter/ 1 in., max pump size/ 12 cfm, flange both ends, absorbent material/ zeolite
01-370-3026
Eddy Current Probe Set
Used on f/a-18 acft.
01-370-3743
Ultrasonic Test Transducer
01-370-7106
Ultraviolet Metals Examini Light
100-watt; 4500 uw/sq.cm; hand-held; includes transformer, cords
01-370-9922
Radiographic Ind X-ray Apparatus
01-370-9923
Radiographic Ind X-ray Apparatus
Page: 32 ...