NSN 6630-01-444-4280 NIIN 014444280 — Water Quality Analysis Set

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6630-01-444-4280
6630014444280
Description:
WATER QUALITY ANALYSIS SET
NSN Assigned:
29-SEP-10
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6630-01-444-4280 Specification Set by the OEM (see RNCC code 3)

Nonsupply Items And Quantities AJKD:

dr/2010 spectrophotometer 1; digital titrator 1; portable ph meter 1; portable conductivity/tds meter 1; procedures/instrument manual 1; battery eliminator/charger 1; carrying cases 2; reagents and apparatus; storage space for 2100p portable turbidimeter

Part Name Assigned By Controlling Agency CXCY:

water quality analysis set performs 27 tests

Special Features FEAT:

performs the following 27 tests: acidity, alkalinity, bromine, calcium, carbon dioxide, chloride, chlorine, free and total, chromium, conductivity, copper, dissolved oxygen, fluoride, hardness, iodine, iron total, manganese hr, nitrogen ammonia, nitrogen nitrate, nitrogen nitrite, ph, phorphorus reactive, phosphorus total, residue NON-Filterable, silica, sodium chormate, sulfate, and sulfide

Supplementary Features SUPP:

this is a replacement for 6630-01-154-1535; af ta SP06

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
97-0251
Cage Code:
89875
RNCC:
5
RNVC:
1
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
2922400
Cage Code:
91224
RNCC:
3
RNVC:
2
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
DREL 2800
Cage Code:
91224
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
DREL/2010
Cage Code:
91224
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
CTCHV
SADC:
Part Number:
26700-05
Cage Code:
91224
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
26700-05
Cage Code:
91224
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
26700-05
Cage Code:
91224
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
97-0251
Cage Code:
89875
RNCC:
5
RNVC:
1
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
2922400
Cage Code:
91224
RNCC:
3
RNVC:
2
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
DREL 2800
Cage Code:
91224
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
DREL/2010
Cage Code:
91224
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
CTCHV
SADC:
Part Number:
26700-05
Cage Code:
91224
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
9Z
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32948
FIIG:
A23800
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "WATER QUALITY ANALYSIS SET"

A collection of chemical reagents and chemical analysis equipment used for on-site water analysis to determine quality of raw water source for treatment; to determine type of water treatment process required; for establishing and maintaining optimum operating conditions of treatment; and to determine suitability of wastewater effluents for discharge to the environment. Excludes water quality control set.

6630-01-444-4280 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
Y
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) Y

Indicates information is in the hazardous materials information resource system (hmirs).

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.