NSN 6630-01-268-2117 NIIN 012682117 — Ph Meter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6630-01-268-2117
6630012682117
Description:
METER,PH
NSN Assigned:
25-NOV-87
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6630-01-268-2117 Specification Set by the OEM (see RNCC code 3)

Circuit Current For Which Designed AACT:

ac

Overall Length ABHP:

5.000in. ⁓5-1/64"

Overall Height ABKW:

4.250in.

Overall Width ABMK:

9.500in.

Indicator Type AMKD:

digital display

Installation Design AMQY:

bench

Display Type BFQN:

light emitting diode

Display Digit Quantity BFQP:

5

Smallest Graduation Unit BGTT:

0.01 ph

Measurement Range BHMW:

+0.0/+14.0 ph single indicator single range

Accuracy Rating CTPT:

porm 0.05 pct of reading porm 1 pct of reading single indicator single range

Display Color CTQH:

white single indicator single range

Nuclear Hardness Critical Feature NHCF:

nonhardened

Style Designator STYL:

rectangular or square

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
050100
Cage Code:
30260
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
051722
Cage Code:
15481
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
13-641-709
Cage Code:
22527
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
501
Cage Code:
30260
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
34104-222
Cage Code:
6J233
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
050100
Cage Code:
30260
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
501
Cage Code:
30260
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
13-641-709
Cage Code:
22527
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
34104-222
Cage Code:
6J233
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
F
MSDS:
SADC:
Part Number:
051722
Cage Code:
15481
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
MB
Status:
H
MSDS:
SADC:
Part Number:
050100
Cage Code:
30260
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
13-641-709
Cage Code:
22527
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
501
Cage Code:
30260
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
34104-222
Cage Code:
6J233
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
MB
Status:
F
MSDS:
SADC:
Part Number:
051722
Cage Code:
15481
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
MB
Status:
H
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
42678
FIIG:
A310A0
Concept No.:
App. Key:
G
Cond. Code:
1
Status:
A
STYLE DESIGNATOR RECTANGULAR OR SQUARE style nsn 6630-01-268-2117

Definition Definition of approved item name (AIN): "METER,PH"

An electrical instrument embodying a potentiometer circuit with suitable electrodes to determine the effective acidity or alkalinity of a solution in the measuring of hydrogen ions concentration.

6630-01-268-2117 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.