Electrical And Electronic Properties Measuring And Testing Instruments FSG 66 — FSC 6625

NSN
NIIN
Name
Details
01-397-8242
Instrument Shunt
Used on low density radio communication link.
01-397-8268
Voltmeter
Used on low density radio communication link.
01-397-8272
Voltmeter
Used on low density radio communication link.
01-397-8312
Plug-in Unit Electronic Chassis
Used on f-15 ais. original name mainframe, electronic test; 8-slot mainframe for modular measurement system
01-397-8338
Current Sensor
01-397-8348
Indicator Control
01-397-8420
Signal Generator
Synthesized sweeper
01-397-8424
Test Set Coupler
Used on 10k isolation resistor assy, cantass towed arry sys, tag repair facility.
01-397-9843
Special Scale Meter
Used on low density radio communication link.
01-397-9847
Special Scale Meter
Used on low density radio communication link.
01-398-0662
Oscilloscope
01-398-0663
Test Probe-lead Assembly
01-398-1150
Control-power Supply
01-398-1210
Voltmeter
01-398-1214
Electrical-electronic Test Case
01-398-1445
Oscilloscope
Switchable bandwidth limits:ac coupled (lower -3db freq) : 10 hz; lf reject (lower -3db freq) :400 hz; bandwidth limit: (upper -3db freq) : 30 mhz; 2 channels; 1 mv/div to 5v/div vertical sensitivity range, vert. gain accuracy:porm 1.25 pct. of full scale; vert. resolution: 8 bits over 8 div (porm 4 pct.) , 10 bits via hpib w/averaging (porm 0.1 pct.) ; max. sample rate: 1 gs a/s; waveform record lgth: 8001 pts real time, 501 repetitive; input coupling: ac, dc; autoscale feature; 17 automatic pulse paramenter measurements; waveform storage; external trigger functions: glitch, edge, pattern, state, dig. delay x time/event, tv, time qual.pattern
01-398-1529
Test Probe-lead Assembly
01-398-1602
Oscilloscope
01-398-1621
Decade Capacitor
01-398-1879
Test Adapter
01-398-1880
Test Adapter
01-398-2174
Electronic Systems Test Set
01-398-2175
Test Electrical-electron Fixture
29.800" overall length
01-398-2176
Test Electrical-electron Fixture
29.900" overall length
01-398-2218
Multimeter
Used on low density radio communication link (ldrcl).
01-398-2553
Electrical Cable Test Set
01-398-2781
Electronic Digital Reado Counter
Used on an/apm-233. 16.750" overall length 14.000" overall width kopt 2 measures power of signals &allows power offsets from M99.9 db to 99.9 db; opt 4 high stability time bases; opt 8 gpib ieee 488-1978 (standardin model 575b) ; opt WB83 includes slide, bracket support, rack mount, spacer& hardware; front panel selected service diagnostics/user info; sample rate from 100 msec to 10 sec hold position; reset, offset,
01-398-2917
Microcircuit Programmer
01-398-2918
Decoder-receiver Test Set
01-398-2919
Audio Test Set
01-398-2920
Transmitter Test Set
01-398-2921
Amplifier Test Set
01-398-2922
Navigation Test Set
01-398-2925
Electrical-electron Plug-in Unit
01-398-2937
Radar Test Set
01-398-2980
Test Program Set
16:9 aspect ratio, pdc
01-398-3087
Multiple Scale Meter
Single-setpoint 10 a relay
01-398-3876
Electronic Digital Reado Counter
4.000" overall length
01-398-4102
Microcircuit Programmer Adapter
Used on an/arc-190(v).
01-398-4187
Oscilloscope
Internal thermal plotter; 3.5 inch floppy drive; analysis firmware; scaling firmware; four channel; color monitor; eight bit resolution; sweep frequency range 150.0 megahertz
01-398-4338
Test Lead
01-398-4380
Test Prod Tip
01-398-4483
Microphone Simulator
01-398-4760
Radio Frequency Detector
01-398-4951
Oscilloscope
Used on aircraft model p3c peculiar. oscilloscope, radar test set
01-398-5099
Signal Generator
24.300" overall length 19.000" overall width
01-398-5148
Electrical-electron Plug-in Unit
Used on f-15e electronic test station. bandwidth: 1.3 ghz; channels: two 1 x 4, one 1 x 3; impedance: 50 ohms; max voltage: 42 vdc; max current: 1a; no switched shield; 3 multiplexer banks are isolated from each other
01-398-5149
Electrical-electron Plug-in Unit
Used on f-15e electronic test station. 32 channel; max voltage: 250 vdc; max current: 2a; relay type: armature; thermal offset: less than 3uv; 2-wire, can switch both high
01-398-5150
Electrical-electron Plug-in Unit
Used on f-15e electronic test station. 6.5 digits; 7 functions: dc voltage: (90 day, tcal porm 5 deg. c) voltage range: 250 volts/30 mv; dc current: (90 day, tcal porm 5 deg. c) range-1.5 amps/300 ua; resistance: (2
01-398-5151
Electrical-electron Plug-in Unit
Used on f-15e electronic test station. consists of 8 relays, contact configuration: spdt (form c) ; max. voltage: 125 vdc; max. current: 10 a; bandwidth: 1 mhz; b suffix designates screw terminals
Page: 888 ...