01-327-2108
Test Probe
Used on watchman test equipment.
01-327-2109
Test Probe
Used on watchman test equipment.
01-327-2111
Electrical-electronic Test Cover
Used on special support equipment-fleet workshop,torpedo mk46mods,spare parts special tools tester assy continuity,naval undersea warfare engineering.
01-327-2390
Digital Display Indicator
Angular range 000.0000 deg to 359.995 deg
01-327-2942
Digital Display Indicator
Opt 5 is front panel local control; opt 6 is front panel readout; opt 7is 200 v bit; opt 8 is independent amplitude programming; opt 333 is bgib, ieee-488-1975; 100 w max; 25 lbs; output signal 0-3 vrms; programming time: 500 microsec; phase angle range: 0-359 deg in 1 deg steps; amplitude programming: ranges: 0.5-130 v in 0.1 steps; accuracy rating: 1 hz first indicator, first scale; 1.00 degree angular calibration range; 0.25 volts
01-327-2946
Radio Frequency Monitor
Used on missile radar alt test set. 4.125" overall length 1.828" overall width configured so mrata users can make calibration adjustment
01-327-3018
Electronic Circuit Plug Test Set
01-327-3019
Electronic Systems Test Set
Used on an/apr-46a; ac-130h gunship program. microwave signal generation: frequency 0.01-18.5 ghz, amplitude minus 140-plus 10 dbm, phase noise minus 100-minus 148 dbc/hz at 20 khz offset, modulation am/fm/pulse; pulse generation:20 nanosec-950 millisec; measurement: frequency to 18 ghz, cw power minus 70-plus 20 dbm, spectrum analysis freq 100 hz-22 ghz, amplitude minus 130-PLUS30 dbm, ssb phase noise to minus 145 dbc/hz, waveform analysis single shot freq dc-50 mhz, repetitive bandwidth 10hz-300 mhz, 4 waveforms, 2 channels, scaler analysis 0.01-20 ghz, dynamic range minus 55-plus 14 dbm, voltage meassurement 0.3 ma to 1.4 a (dc)
01-327-3123
Digital Data Electronic Analyzer
16.750" overall width
01-327-3649
Frequency Mixer Stage
Used on 4920-01-309-8081 test station,control f-14a acft.
01-327-3683
Digital Components Test Bench
Used on helicopter h-53.
01-327-3839
Noise Generator
Used on 6625-01-310-9819; 4920-01-288-6790; f15e acft. 2.450" overall length 0.750" overall width
01-327-3884
Signal Generator
20.500" overall length 16.750" overall width rf connections on rear panel
01-327-4145
Electronic Systems Test Set
01-327-4755
Power Radio Frequency Divider
2.25 in. lg; 1.38 in. w; 1.25 in. h less connectors; four 0.15 in. dia mtg holes on 2.95 in. by 1.1 in. mtg ctr; four rf connectors for three way power division; 1 to 200 mhz freq range; 40 db typical middle isolation; 0.4 db typical middle insertion loss; 20 deg max middle phase unbalance; 0.2 db max middle amplitude unbalance
01-327-4759
Ammeter
1.290" overall length 1.750" overall width ruggedized fan shape flush mtg
01-327-4769
Function Electronic Te Generator
Used on an/fsq-115(v) arts.
01-327-4792
Test Adapter
C/o 6 cable assemblies; 2 waveguides; 1 adapter waveguide to coaxial
01-327-5008
Power Radio Frequency Divider
dim 0.500in w; 0.400 in h; to-5 series freq range 57.0 to 63.0 mhz
01-327-5026
Signal Data Converter
4.800" overall length 3.700" overall width c/o carrying case, 2 alkaline batteries, plug-in power supply, male/female bnc adaptor, instruction/service manual; max output voltage 0.5
01-327-5030
Current Sensor
Used on used with power meter part/target acquisition.
01-327-5031
Current Sensor
Used on used w/rf power meter p/n 4421. 5.219" overall length 2.500" overall width afrequency range rating is 25.0 to 1000.0megahertz; battery case is not provided; unpackaged unit weight is 1.690 pounds; part name assigned by controlling agency is radio frequency power sensor
01-327-5092
Frequency Standard
Used on precise time & frequency console agmc/mlee 6625-01-012-5255. 19.000" overall width output frequencies 1 megahz, 5megahz, and 10megahz; rack-mountable receiver/display assembly, antenna/preamp
01-327-5104
Test Set Case
Used on mainframe,p/n lts-4300,fiber optic loss test set.
01-327-5153
Radio Frequency Detector
Used on detector, coaxial, positive output, option 003, hewlett packard p/n 423b-003. 11.000" overall length 5.125" overall width frequency range 0.01 to 12.4 ghz; diode type, low-barrier schottky; positive polarity output
01-327-5323
Test Probe-lead Assembly
01-327-5359
Test Probe
Used on 6625-01-282-3746.
01-327-5448
Spectrum Analyzer
427.000mm overall length 325.000mm overall width
01-327-6012
Voltmeter
Used on 4920-01-227-4939 dqadints. 19.000" overall length 16.750" overall width auxiliary displays for lock frequency rectangular surface mtg
01-327-6690
Data Entry Joystick
01-327-7149
Electrical Frequency Meter
Used on an/fsq-151(v) arts. 8.300" overall width rack
01-327-7150
Wattmeter
Used on an/fsq-151(v),arts. 17.250" overall length 14.800" overall width frequency range 100 khz-50 ghz; 3digit, seven segment led display for requested power (dbm) ; 4 digit 7 segment led display to measure power (watts or dbm) rectangular or square
01-327-7229
Spectrum Analyzer
25.000" overall length 16.750" overall width 80.0 to 100.0 db dynamic range; porm 0.25 typical level accuracy; 50, 75, 1 mega ohms inputs; 3 hz resolutionbandwidth
01-327-7913
Special Scale Meter
6.300" overall length 5.750" overall width 0 to 300psi rectangular flush mtg
01-327-7914
Special Scale Meter
7.500" overall length 4.840" overall width 0 to 4000 kilowatts round flush mtg w/4 tabs
01-327-8378
Electrical Frequency Meter
01-327-8732
Test Electrical Panel
01-327-9265
Special Scale Meter
01-327-9363
Special Scale Meter
Round flush mtg
01-327-9364
Special Scale Meter
Round flush mtg
01-327-9365
Special Scale Meter
Round flush mtg
01-327-9366
Special Scale Meter
Round flush mtg
01-327-9490
Digital Display Indicator
Used on 6630-01-234-6793. indicator digital display e.i. NSN6630012346793 analyzer MDL4207 for use on analyzer, hematology, centrifugal; mdl. 4207
01-327-9491
Ammeter
Ammeter milliamper meter e.i. nsn 6525012405830 x-ray apparatus milliamper meter; end item application 6525-01-240-5830; x-ray apparatus, radiographic, medical; cage 0EX38; mdl no. clinix r.m.
01-327-9575
Field Strength Meter
01-327-9652
Test Probe-lead Assembly
01-327-9839
Radar Set Test Bench
Used on apq-170.