01-250-1074
Voltmeter
2.210" overall length 3.700" overall width ruggedized; internal light wells with t-11/4 size lamps in standard voltage of 28 volts paint surface treated rectangular flush mtg
01-250-1075
Voltmeter
2.210" overall length 3.700" overall width ruggedized; internal light wells with t-11/4 size lamps in standard voltage of 28 volts paint surface treated rectangular flush mtg
01-250-1077
Ammeter
2.210" overall length 3.700" overall width ruggedized paint surface treated rectangular flush mtg
01-250-1260
Electrical Test Set Subassembly
Used on an/alm-233; an/alq-184 se. provides min & max loads as specified in the lvps scds (G134671 & G134672) ; each power supply voltage is accessable on the front of the lvps load box for ease of measurement
01-250-1264
Voltmeter
5.060" overall length 4.000" overall width 2.5 watt power consumption rectangular flush mtg
01-250-1265
Ammeter
5.060" overall length 4.000" overall width 2.5 watt power consumption rectangular flush mtg
01-250-1303
Electronic Digital Reado Counter
16.750" overall length 14.000" overall width 10 watt (plus 40 dbm) damage protection; 10 dbm auto amplitude discrimination; 250 ms acquisition time; 400 mhz/sec tracking speed; 20 mhz pp fm tolerance to 10 mhz; 50 measurements persec; crystal freq 10 mhz; square wave, 1v p-p min; 3 bands: 10-100 mhz, 10 mhz-1 ghz, 1 ghz-18 ghz
01-250-1373
Radio Test Set
01-250-2665
Relay Test Set
Used on ch-53 acft.
01-250-3144
Electrical Test Set Subassembly
Component type
01-250-3145
Electrical Test Set Subassembly
Used on nsn is cancelled: 4940-00-895-5280.
01-250-3438
Power Radio Frequency Divider
Iron alloy; 1.350 in. lg; 0.500 in. w; 0.130 in. h; isolation 20 db; vswr common port 1.2:1; vswr divided port 1.2:1; amplitude balance 0.300 db; rf operating power 100 watts; input power unbalance 10 watts; warm up time 5 minutes; phase relationship between any two adjacent ports shall be 90 deg; non-operating ground temperature -65 deg f to +200 deg f; operating cold plate temperature -30 deg f to +170 deg
01-250-3440
Fault Locating Indicator
Operating temperature range, -55 to +70 deg c continuous; altitude sea level to 70000 feet
01-250-3477
Electronic Digital Reado Counter
01-250-3872
Electrical Meter Test Set
01-250-3873
Electrical-electron Plug-in Unit
01-250-3874
Capacitance Bridge
6.400" overall length 2.400" overall width operates on 4 standard c cell batteries
01-250-3929
Sweep Generator
01-250-3973
Modulation Meter
01-250-3995
Electronic Digital Reado Counter
01-250-4025
Electrical Frequency Synthesizer
01-250-4271
Sweep Generator
18.400" overall length 16.800" overall width naingenerator, tracking; swept signal source testing components of spectrum analyzer system; freq rng 0.5 to 15000 mhz, resolution 1.0 khz
01-250-4309
Digital Display Indicator
length, 10.90 in.; width, 5.82 in.; operating termperature, -40 deg c to 85 deg c; six line, 40 characters wide; vacuum fluorescent; optical color, blue-green; power rqmts, 5vdc;
01-250-4350
Special Scale Meter
01-250-4351
Special Scale Meter
01-250-4541
Capacitance-inductance-re Bridge
6.800" overall length 3.500" overall width
01-250-4547
Spectrum Analyzer
Consists of mainframe/display, tuning section, and if section