01-085-8914
Noise Generator
01-085-9115
Test Lead
Tin core conductor single conductor surface treated
01-085-9221
Power Radio Frequency Divider
Shall meet requirements of mil-e-16400g; frequency range of 50 khz-20mhz; insertion loss of 0.5 db; impedance of 50 ohms; vswr of 1.3:1; power (matched loads) 2w; housing is aluminum alloy 356-T6 per mil-c-11866, composition 2; housing finish is tin-plated per mil-g-45204, TYPE1, grade c, class 1; 11380 in. lg, 0.780 in. max w, 0.600 in. max h; operating temperature is M54degree c to plus 95 degree c
01-085-9222
Power Radio Frequency Divider
Shall meet requirements of mil-e-16400g; frequency range of 10-500 mhz; insertion loss is 0.6 db for frequency of 400-500 mhz; impedance 15 50 ohms; vswr 15 1.3:1; power is 3w; housing is aluminum alloy 356-T6 per mil-c-11866, composition 2; housing finish is tin-plated per mil-g-45204, type 1, grade c, class 1; 1.380 in. lg; 0.780 in.max w; 0.600 in. max h; operating temperature is M54 deg c to P95 deg c
01-085-9337
Voltage Standard
1.500" overall length 1.500" overall width
01-085-9588
Voltmeter
1.800" overall length 3.500" overall width ruggedized rectangular flush mtg
01-085-9689
Stroboscope Disk
01-086-0215
Test Adapter Set
Test package, identification; usedin conjunction with an/gsm-228 antenna test station for the f-15 series aircraft
01-086-0248
Current-voltage Standard
4.870" overall length 4.000" overall width
01-086-0488
Digital Display Indicator
Used on an/mst-t1.
01-086-0489
Digital Display Indicator
Used on an/mst-t1.
01-086-0720
Electrical Power Test Set
01-086-0744
Coordinate Data Recorder
Pen drive, stepping motor, 50 pulses/sec, step size 4 steps/mm; automatic reset, calibrated dial; remote reset, independent; reset report, response counter; clutch release; report reinforcement marker; paper drive, alum. platen, synchronous motor; glass reservoir, approx 72 hr ink supply; paper used 6.5 in. w; recording elements 24-28 vdc, 2 amp; paper drive motor 110 vac, 60 hz; 30 cm/hr, solid state compatible
01-086-0760
Instrument Shunt
3.250" overall length 1.750" overall width
01-086-0819
Test Probe
5.000" overall length designed for connections over component leads to 0.040 in. dia
01-086-2041
Voltage Calibrator
8.500" overall width
01-086-2271
Multimeter
Used on f/fb-111 avonics test station. digital
01-086-3130
Test Probe
9.000" overall length 4.500" overall width
01-086-3241
Voltmeter
01-086-3410
Power Factor Meter
6.200" overall length 2.750" overall width
01-086-3419
Electrical-electronic Test Case
Used on avu-8 b/a, f-16 a/b acft. case, indicator case indicator subassembly; includes p/n 50343520040 case, indicator
01-086-3755
Wattmeter
01-086-3795
Digital Display Indicator
Ccathode ray tube displays tactical anti-submarine warfare information; 28 vdc, 150w primary power; 28vdc 5w lighting; 115 v, 400 hz, 1 phase, 10 va elapsed time indicator; 10.5 in.by 13.75 in.by 8.5 in.;
01-086-4295
Test Electrical Panel
01-086-5354
Signal Generator
Used on f-15 acft age.. 19.370" overall length
01-086-5510
Frequency Calibrator
1.500" overall length 1.500" overall width
01-086-5912
Transmission Line Test Set
Option 10 is hp-ib interface
01-086-5965
Directional Co Detecting Element
2.000" overall length used on faa model 4301-011 wattmeter
01-086-5980
Oscilloscope
19.880" overall length 19.000" overall width
01-086-6179
Electronic Switch
01-086-6180
Electronic Switch
01-086-6671
Ammeter
2.450" overall length 3.250" overall width enamel lusterless surface treated rectangular flush mtg
01-086-6959
Coordinate Data Recorder
10 in., 12 speed, 16-range, 1mv-100 volt multi-range, instant on, high speed solenoid operated pen lift
01-086-6960
Coordinate Data Recorder
3 pen, 110/115 v, noncontrolling recorder, 70-80 ohm, 3/4 in. per hr is std chart speed
01-086-6961
Coordinate Data Recorder
Full scale ranges 1, 2, 5, 10, 20, 50 mv-0.1, 0.2, 0.5, 1, 10 v; effective chart wdth 250mm; chart speeds 5, 10, 20, 40, 80, 160 mm/min; 17.25 in. w, 5.5 in. h, 17 in. d; temp marker, fully adjustable zero, zero check switch
01-086-6972
Voltmeter
2.538" overall length 4.846" overall width rectangular flush mtg
01-086-6973
Ammeter
7.669" overall length 4.846" overall width double set point rectangular flush mtg
01-086-6974
Ammeter
2.480" overall length 2.702" overall width rectangular flush mtg
01-086-6975
Electrical Frequency Meter
2.656" overall length C1 round flush mtg
01-086-6976
Instrument Shunt
01-086-7005
Oscilloscope
14.600" overall length 9.300" overall width
01-086-7063
Arbitrary Scale Meter
2.595" overall length 2.093" overall width ruggedized paint surface treated rectangular flush mtg
01-086-7091
Electrical Meter Subassembly
01-086-7578
Signal Data Converter Test Set
Used on an/gsm-284.
01-086-7597
Digital Display Indicator
Sgl unit; capable of individual displays; plug in mtd;
01-086-7609
Ammeter
1.684" overall length 3.000" overall width rectangular flush mtg
01-086-7741
Signal Data Recorder
4.750" overall width multi-range chart recorders
01-086-8063
Control Test Set
Nain: test stand, electronic control unit; provides all necessary electrical stimuli
01-086-8064
Selector Test Set Coupler
Nain: channel selector; provides test point access for maintenance
01-086-8065
Digital Data Electronic Analyzer
A-a, a-d, and d-a measurements; automatic measurement sequencing; user-level keyboard programming; non-volatile program storage; built-in data modem