01-583-0381
Oscillator Subassembly
Dual phase lock; 21.5 ghz
01-583-0477
Special Scale Meter
Used on mtrdgtdmc-b-1-4-20ma-m24742d-f23-g2-dc-a. dmc digital meter/controller nema 4x enclosure; weather tight; 2 relays with analog output; 4-20 defines analog output type
01-583-0907
Radio Frequency Radiati Absorber
35.750" overall length 17.750" overall width description: thin, flexible, resonant-tuned foam absorber, charcoal gray to black, 17db min at 9.375ghz, the arc-ss-11004 (salisbury screen) absorber is designed using quarter wavelength absorption principle, this ensures effective cancellation incident wave at front of absorber, at target frequency
01-583-1078
Oscilloscope
Used on GPETE. 13.400" overall width 600 mhz; 4 input channels; 5 gs/s, 12.5 mpts/ch (10 gs/s, 25 mpts/ch in interleaved mode) ; 10.4 in color touch screen display; trigger modes: normal, auto, single, stop; interfaces: 10/100/1000base-t ethernet interface (rj-45 connector) , 5 usb 2.0, external monitor port: standard 15-pin d-type svga-compatible db-15; serial port: db-9 rs-232
01-583-1160
Field Strength Meter
Used on e25 aircraft. model 6010 hall effect gaussmeter weight: 8.8lb; communication ports: rs-232; rechargeable, sealed lead acid
01-583-1167
Antenna Radiation Patt Indicator
Site analyzer 25mhz - 1700mhz, with power measurement capability
01-583-2040
Electronic Equipment Parts Kit
Used on 6640-01-547-1760.
01-583-2456
Electronic Switch
01-583-2683
Radio Frequency Radiati Absorber
20.000" overall length 16.000" overall width iron loaded silicon rubber sheet
01-583-2773
Electronic Systems Test Set
Central collection point for pulses captured by up to 16 pulse testers; timestamps pulses with 1 msec resolution; 9600 baud rate; 5v ttl compatible output, open collector, active low signal triggers; 1024 pulses per test file
01-583-2774
Transponder Set Test Set
Transponder test modules 1, 2, 3/a, c, s, 4 mode 5; interrogator test modules modules 1, 2, 3/a, c, s, 4, mode 5, tcas
01-583-2979
Electronic Systems Test Set
Used on u-2 aircraft.
01-583-3250
Radio Test Set
Used on any tactical communications system. aeroflex 3500 series portable radio communications test set portable; wighs 8.5 lbs with battery; weatherproof case; op temp range: -20 deg to +50 deg c; rechargeable battery; with external attenuator provided, up to W00 watts; battery lastes 5 hours without being recahrged
01-583-3273
Electrical-electron Plug-in Unit
01-583-3276
Electrical-electron Plug-in Unit
01-583-3784
Electrical-electronic Test Case
01-583-4416
Electrical-electron Plug-in Unit
Plug in unit, electrical
01-583-4468
Test Electronic Syste Controller
Controller, test
01-583-4486
Digital Display Indicator
Used on nuclear power plants; stud elongation inspection kit. 0.0 to 1.0 inch/ 0.0-25.4 mm range; flat back; inch/metric conversion; zero setting to any position
01-583-4742
Test Adapter
Used on 6625-01-449-8480 meter, noise level. adapter to connect calibrator calibrator adapter; used to attach device to calibrate noise level meter; for use with end item noise level-impulse integrating meter, 6625-01-449-8480
01-583-5022
Electrical Cable Test Set
01-583-5473
Semiconductor Device Test Set
Waveform:sine wave; number of scan pins per channel:40; scan modes:namual or atomatic; weight:6 lbs
01-583-5736
Radio Test Set
Used on model 3500, 3500a.
01-583-5752
Electrical-electro Accessory Kit
Used on model 3500, 3500a.
01-583-5788
Battery Test Set
Used on mrap-rg-31.
01-583-6157
Power Factor Meter
Datalogging ac/dc power clamp-on meter
01-583-6234
Signal Generator
Microwave analog signal generator options: 520 frequency range from 250 khz to 20 ghz; unt adds internally or externally driven am, fm
01-583-6334
Ammeter
Used on knolls atomic power lab special project management systems. 1.460" overall length 3.015" overall width ruggedized blue dot panel meter, 0-15 amps ac rectified rectangular flush mtg
01-583-6405
Digital Data Coupler
Used on gas chromatography. column nut column nut (fitting) for ms interface
01-583-6674
Ammeter
2.5m output cable; bnc connector; can be used with digital multimeters using a bnc-to-banana jack adapter clamp-on
01-583-6781
Modulation Meter
Used on GPETE. 18.750" overall length 17.250" overall width cage: am/fm modulation meter has unique combination of measurements: am, fm rectangular surface mtg
01-583-7096
Ammeter
7.000" overall length 5.250" overall width powered by 1d-cell portable
01-583-7315
Electrical Cable Test Set
Test set, electrical
01-583-7317
Electronic Systems Test Set
Used on ab-412sp agusta helicopter.
01-583-7379
Voltmeter
Gauge kysor vdc P5, electronic control unit for kysor multiplex gauge package
01-583-7464
Test Lead
Name on mfgr's data-reference electrode; senses an electrical current in the water when testing the mercathode system; use to check hull potential
01-583-7502
Signal Data Generator
Used on ea-6b icap iii aircraft. bit-cal geenerator assy
01-583-7506
Signal Data Generator
Used on ea-6b icap iii aircraft. misc input, output assy
01-583-7574
Special Scale Meter
01-583-7603
Multimeter
Used on united kingdom desert hawk 3 unmanned air system. fluke 115 multimeter
01-583-7782
Fault Locating Indicator
Used on nm113f3, armored personnel carrier vehicle. driver indicator box assembly used on 4265401 powerpack mounting kit
01-583-7795
Electrical Meter Assembly
Used on 2355-01-529-2246 mine resistant vehicle,cougar (jerrv) 6x6. pnl inst gauge cluster fpi
01-583-8059
Digital Display Indicator
Used on 1410-01-087-6343 guided missile,intercept aerial. indicator, digital, humidity
01-583-8440
Decade Inductor
Used on power module. inductor, 360 micro assemlby, power module, vsfd mod 2; nha; 900-41800
01-583-8480
Electronic Altimeter Test Set
Discrete delay altimeter test
01-583-8747
Test Probe-lead Assembly
01-583-8748
Test Probe-lead Assembly
01-583-9069
Local Area Network Analyzer
10.300" overall length 9.200" overall width optiview series iii integrated network analyzer pro gigabit with removable hard drive