01-547-6454
Oscilloscope
350 mhz bandwidth at 50 ohms; flat panel lcd display; 800 x 600 svga; touchscreen; 8 bit verticle resolution; one PP007 (2.5mm) probe per channel
01-547-6455
Electrical-electronic Test Case
Used on an/tpn-31a, ground control approach system. 27.200" overall length 27.500" overall width watertight, crush
01-547-6521
Electrical Test Set Subassembly
01-547-6647
Multimeter
Used on 5180-01-460-9328 tool kit, electronic system.
01-547-6839
Cable Breakout Adapter
Used on the trompeter.
01-547-6841
Electronic Equip Maintenance Kit
Used on hp laser jet 5100 series printers. exchange printer maintenance kit for 220 volt printer
01-547-7151
Digital Display Indicator
Used on ecp n18-574 ty 18b,e&e adapter.
01-547-7353
Multimeter
Two inputs
01-547-7798
Instrument Shunt
Current shunt consists of 12 shunts from 10ma up to 5a, the 40a shut adds 10a
01-547-7925
Electronic Equip Maintenance Kit
Used on e-2c support equipment.
01-547-8970
Instrument Shunt
Used on cvn nuclear reactor boundry area. name: current shunt
01-547-9061
Computer Test Set
Used on test set, computer. adu-892/3, tester 120vac, 60hz, operating & storage temp: -20 to +55 deg c
01-547-9103
Test Set Case
Carrying case, model 605 ht/aht water test kit
01-547-9162
Radio Frequency Radiati Absorber
Used on 59901-1/a/a37u-36 deploy release mechanism part of meggitt aerial gunnery target system ags-36. 3.200" overall length 2.500" overall width
01-547-9287
Video Integrating Analyzer
Used on automated test equipment. spectroradiometer capable of measuring luminance, radiance, tristimulus values, correlated color temperature, wavelength range 380 to 780nm, spectral accuracy porm 2nm, spectral bandwidth equal to or greater than 2.5nm dependant on aperature height
01-547-9347
Current Sensor
Used on dc lop4801134-30.
01-547-9350
Current Sensor
Used on dc lop 4801134-31;dc lop 4801134-32.
01-547-9648
Multimeter
201.0mm overall length 95.0mm overall width multimeter 87v ex measurements up to 1000 v / 10 a, outside the ex-hazardous area; background lighting; standard delivery device, ex-holster, battery, measuring leads, alligator clips, thermocouple, type k, operating instructions; working temperature M20.0 to P50.0 deg c; reference humidity range 0 to 80 pct at 0 to 35 deg c; battery 1 x 6LR61, 9 v block battery; operating time approx 400 hours without background lighting; weight 650 g hand-held
01-547-9675
Electronic Digital Reado Counter
Time interval, frequency radio
01-547-9956
Digital Display Indicator
Used on controller.
01-548-0120
Oscilloscope
Four channel oscilloscope ambient temp operating m 15.0 to p 55.0 deg c; nonoperating m 62.0 to P85.0 deg c; altitude operating to 4600 m; operating temp decreases 1deg c for each 1000 ft above 5000 ft; nonoperating to 15000 m; vibration operating 15 minutes along each of three axes at a total displacement of 0.025 inch p-p with frequency varied from 10 hz to 55 hz in one-minute sweeps; humidity operating
01-548-0228
Spectrum Analyzer
Handheld; daylight viewable transflective color display; built-in pre-amplifier; zoom-in zoom-out display; one 1hz-3mhz in 1-3 sequence rbw's
01-548-0237
Spectrum Analyzer
100 khz to 4 ghz; supports radiation measurements; manual or automatic control; vga display; up to 6 markers; pass/fail verdict with limit templates; high-precision; frequency measurements; am & fm demodulation; digital signal processing with reloadable digital if
01-548-0285
Null Meter
Used on automated test equipment. meter, dc null has lcd status display for range offset, filter response time, input impedance, zero/operate mode, input offset mode, isolated output mode rectangular or square
01-548-0486
Test Adapter
Used on 83496a/b. 3.5mm female, type-n male adapter
01-548-0527
Electrical-electron Plug-in Unit
50 mhz.
01-548-0580
Signal Generator
Used on U-2.
01-548-0587
Oscilloscope
Used on U-2.
01-548-0588
Oscilloscope
Used on U-2.
01-548-0589
Signal Generator
Used on U-2.
01-548-0592
Spectrum Analyzer
Used on U-2.
01-548-0596
Monitor Panel
Used on U-2.
01-548-0898
Ammeter
Used on 6130-01-500-3401. 50 amp meter, panel mount kit: ampmeter, mount bracket, hardware
01-548-1016
Electronic Switch
1.600" overall length navigation data distribution system (navdds) switch
01-548-1377
Ohmmeter
Used on U-2.
01-548-1383
Signal Generator
Used on automatic test equipment. 20.300" overall length 16.800" overall width this E8257d has option 1ea (high output power) , 1E1 (step attenuator) , 1eh (improved harmonics below 2ghz) , H1k (extended low frequency coverage 100khz to 250khz) , HE1 (afmetcal contract) , power requirements (auto selected) 90 to 132 vac at 47 to 64hzor 195 to 267vac at 47 to 64hz, operating tempe rature range 0 to 55 degrees celcius, storage temperature range -40 to 70 degrees celcius, weight less than 48 pounds net, shipping weight less than 68 pounds, all specifications are after a 45 minute warn-up time
01-548-1851
Power Supply Test Set
Used on U-2.
01-548-1973
Phase Monitor
Used on hpu motor controller 16243200.
01-548-3085
Frequency Calibrator Set
Used on automatic test equipment. will include noise generators with type n
01-548-3645
Electronic Digital Reado Counter
Used on general purpose electronic test equipment.
01-548-3723
Radio Frequency Monitor
01-548-3724
Electronic Systems Test Set
Msd-V2fr (us version) non-wireless
01-548-3852
Multimeter
Hand-held
01-548-3922
Special Scale Meter
7.125" overall length 2.750" overall width manometer psi range 0-5 portable
01-548-4035
Voltmeter
17.375" overall length 17.125" overall width rectangular or square
01-548-4075
Electrical-electron Plug-in Unit
Used on c-17a support equipment. waveform synthesizer provides the following functions:swept function generator; pulse generator; programmable sequencer;
01-548-4318
Multimeter
Used on test equipment (test). clamp-on multimeter; average responding 3.5 number of digits; cat iii 600v approval
01-548-4403
Test Electrical-electron Fixture
Used on mk48 torpedo maint. spares for ran, fms. (navy) fixture, press test