Electrical And Electronic Properties Measuring And Testing Instruments FSG 66 — FSC 6625

NSN
NIIN
Name
Details
01-541-1001
Voltmeter
1.826" overall length 0.838" overall width rectangular or square
01-541-1173
Instrument Shunt
01-541-1394
Electronic Circuit Plug Test Set
Ramcheck plus memory tester
01-541-1545
Digital Display Indicator
01-541-1982
Signal Generator Modulator
Synthesized signal generator 252 khz to 1030 mhz; 0.01 hz resolution; +20 to -140 dbm output; -100 dbc spurious noise; am, fm, phase, pulsemodulation, digital sweep modes hp-ib
01-541-2311
Test Electronic Syste Controller
Used on AWACS. packaged driver, indexer system reduce setting time, increase slower speed smoothness, reduce audible noise
01-541-2330
Electrical Frequency Meter
Nha is vxi frequency counter
01-541-2332
Directional Co Detecting Element
Elements gold plated for high conductivity; interchangeable with other elements; nist traceable (rf power) standards for accuracy; the 82000 series of coaxial dynamics plug-in elements are calibrated to exacting specifications to assure interchangeability with one another,
01-541-2511
Digital Display Indicator
01-541-2636
Spectrum Analyzer
Used on eurofighter ej200 engine. 79.4mm overall length 72.4mm overall width installation vibration mount
01-541-2749
Digital Display Indicator
Used on flexible engine diagnostic system (feds).
01-541-3882
Electrical Meter Housing
Used on df868 ultrasonic liquid flow meter.. rectangular, surface mtd
01-541-3914
Data Entry Keyboard
Used on df868 ultrasonic liquid flowmeter.. 39-key tactile feedback membrane keypad
01-541-3981
Ammeter
Terminal resistance, special; round 3-1/2 inch, 90 degrees
01-541-4119
Electrical-electronic Test Case
Used on an/usm-674(v)4 protrac. 31.300" overall length 20.400" overall width 5ea locking clasps; telescoping handle with wheels; pad-locking hasp; air/water tight
01-541-4415
Frequency Standard
19.000" overall width 4210a rubidium frequency standard 10mhz rubidium frequency reference; 100khz capability with mopsoption; 1pps disciplining input; minus 130dbc at 10hz ultra low phase noise; rs 232 monitor/control
01-541-4469
Synchro Test Set
Phase angle voltmeter simultaneous data display, ieee-488, RS232, printer port
01-541-4582
Instrument Shunt
01-541-4622
Radar Test Set
Used on mk91 mod2x3, fire control system, gm sse; mk9, tracker illuminator system, sse. test set, radar
01-541-5025
Electrical-electron Plug-in Unit
Used on r-iais 2218000-(). signal gen mod-vxi this is a phase matrix 1140b vxi plug in with options 02, 03, 05, 06; frequency range is 1mhz to 20ghz; module is c size 3 slot; form, fit, function critical
01-541-5203
Electrical-electronic Test Cover
01-541-5288
Ammeter
1.625" overall length 1.750" overall width loadmeter measurement indication is "load", dial pointer is white, dial pointer tip is yellow. this is an a&m model number 135 meter. bezel holes enlarged to .145 in diameter. accuracy is plus or minus 3 percent of full scale. rectangular flush mtg
01-541-5568
Electronic Systems Test Set
Metric acceleration
01-541-5589
Electrical Frequency Meter
8.125" overall width rack
01-541-5679
Test Adapter
Used on 6625-01-524-4047.
01-541-6060
Circuit Breaker Test Set
Used on test set, circuit breaker, prtl.
01-541-6219
Instrument Shunt
Used on shop,equipment nsn 4935-01-136-0233.
01-541-6274
Electronic Digital Reado Counter
Used on masker air flow monitoring system, aft & fwd; prairie air flow monitoring system.
01-541-7157
Electrical-electron Plug-in Unit
13.380" overall length vxibus microwave synthesizer vxi module; min. frequency 2 ghz. max. frequency 20 ghz.; 1 hz. frequency resolution; 25ns frequency switching time; min. output voltage 70.7106781186548mv; max. output voltage 9v; am, fm modulation; am, fm, phase external modulation inputs; 2 size c slots
01-541-7598
Electrical-electro Accessory Kit
Used on wilcox mark 20-category ii/iii ils (mark 20 ). kit, electrical supply
01-541-7699
Network Analyzer
Used on GPETE. ena-l network analyzer 10.4 in. dia. color lcd; 4 measurement channels/4 traces per channel; frequency: 300 khz to 1.5 ghz; vba programming; dynamic range: 115 db; trace noise: 0.005 db rms; sweep types: linear, log, segment, power
01-541-7702
Spectrum Analyzer
Used on aircraft, f-16. 100 hz to 33hz portable spectrum analyzer
01-541-8479
Video Display Pattern Template
Used on aircraft, e-2c hawkeye. 11.000" overall length 11.000" overall width overlay, film next higher assembly nsn 4920-01-536-3831; overlay incorporates a grid type of print on overlay, which include circles - no holes are punched into overlay
01-541-8655
Digital Data Electronic Analyzer
9.220" overall length 4.760" overall width parascope mp wan analyzer operates up to 2.048 mbps multi interface test sets
01-541-8897
Digital Data Electronic Analyzer
50.0mm overall width remote operation, bit error testing
01-541-9062
Electrical Meter Subassembly
Used on 7d3-04854(34712), rta handling control and indic.
01-541-9124
Time Signal Set
Used on an/byk-6 unit 7003 config c, arch sys equip bay 11. time cd translator
01-541-9127
Test Adapter
Used on an/byk-6 unit 7003, arch sys equip bay. bnc t connector
01-541-9136
Digital Display Indicator
Used on approved ecp a&i n3314,15a990021;controller, microprocessor (aeog). display item name text is indicator, digital display
01-541-9403
Electrical Cable Test Set
Used on los angeles class ssn (688). cableiq qualification tester battery type: 4 aa alkaline, or 4aa photo lithium, nihm, nicad; 20 hours of typical use; results storage: up to 250 qualification test results; cable types supported: utp, stp, ftp, sstp, RG6, RG59, audio & security; qualification autotests: 1000base-t, 100base-tx, 10base-t, voip, 1394b s 100, telco, wiremap only, & coax
01-541-9572
Current Sensor
Used on helicopter, black hawk uh-60a; nsn 1520-01-035-0266. 2.187" overall length 1.531" overall width sensing range 1 vdc to 50 vdc, voltage trip point 23 vdc; temp range -55 deg c to 85 deg c; trip point accuracy 2 percent
01-541-9761
Test Adapter
Used on an/byk-6 unit 7003, arch sys equip bay. bnc resist terminator
01-541-9767
Fault Locating Indicator
Used on 49671-8688406-503 ehf trident, ground fault indi. item name text is indicator, fault locating
01-541-9769
Test Adapter
Used on an/byk-6 unit 7003, arch sys tequip bay. bnc male to bnc male
01-541-9838
Voltmeter
Used on mk119 mod0, gun computer cab-japan. 0.588" overall length 2.840" overall width dwg: voltmeter, digital panel; mfr: mini M145 series digital panel meter - dc current negative image: bright red backlighting rectangular flush mtg
01-541-9879
Plug-in Unit Electronic Chassis
44.1mm overall width input voltage 90-250 vac; input frequency 47 hz to 63 hz @ 230 vac, 47 hz to 440 hz @ 120 vac
01-541-9930
Oscilloscope
300 mhz bandwidth; 2.5 gs/s sample rate; 10 k points; 9-bit vertical resolution; 1mv - 10v vertical sensitivity; ac, dc
01-542-0055
Electrical Test Set Subassembly
Used on special aircraft and engine tool and support equipment. control unit memory
01-542-0262
Electrical-electronic Test Cover
Used on support equipment for the v-22. (navy) cover, el screen, nonmetallic, aircraft material
01-542-0319
Pulse Generator
Used on ecass test set,electronic systems an/usm-xxx (tbd).