01-540-5014
Multimeter
Extech 2000a true rms clamp dmm ac/dc voltage 0.0mv to 600v at plus or minus 1.5 per cent; dc current 0.0 a to 2500a plus or minus 1.5 per cent, plus or minus 2 percent greater THAN2000a; 0.0a to 2100a plus or minus 2 percent, plus or minus 2.5 percent at 1000a; 0.0 to 40.00m, omega, plus or minus 1.5 percent; jaws accept up to 1000mcm conductors clamp-on
01-540-5413
Test Prod Tip
Used on K-PEN. delay tip 0.090 in. contact dia. probe; 10 pack
01-540-5422
Data Entry Keyboard
Used on azimuth sailcomp 103ac. 4.800" overall length 1.800" overall width remote keypad unit
01-540-5518
Range Indicator Meter
Used on 2320-01-517-4333. meter odometer lcd
01-540-5658
Special Scale Meter
Used on 2320-01-517-4333. speedometer
01-540-5818
Oscilloscope
13.800" overall width windows xp operating system, quieter cooling motor
01-540-6124
Spectrum Analyzer
Used on GPETE. 170.0mm overall width hand held analyzer internal rechargable battery, 6v to 9v; operating time: 3 hours; lifetime: 300 T0 500 charging cycles; frequency: 100 khz to 6ghz; unit includes the tracking generator.
01-540-6126
Spectrum Analyzer
Used on GPETE. 170.0mm overall width hand held spectrum analyzer internal rechargable battery: nimh battery type fluke BP190 (r&s fsh-Z32) ; battery voltage: 6v to 9v; operating time with tracking generator on: 3 hours; lifetime: 300 to 500 charging cycles; unit includes the tracking generator; frequency: 100 khz to 6 ghz
01-540-6187
Test Adapter Kit
Line impulse analysis adapter module, enhances usefulness of dranetz 606 power line disturbance analyzer; 3 channel; 50/60 hz; porm 5 pct accuracy; 100 amp max rms current; frequency 47 to 63 hz; 1000 amp max peak
01-540-6188
Electrical-electron Plug-in Unit
3 phase plugin ac monitor power voltage analyzer card; 50/60 hz; 50/600 vac
01-540-6192
Electrical Power Test Set
Universal line disturbance analyzer; external trigger; rs-232 port; ul compliant; auto sensing switch; ht 7.480 in; lgth 15.350 in
01-540-6194
Electrical-electron Plug-in Unit
Plug in module monitors 3 phase ac power disturbances from 50/600vac, 45/64hz; used on dranetz 626 model line disturbance analyzers
01-540-6195
Electrical-electron Plug-in Unit
Dc plug in monitor; monitors/records sags, surges, impulses/under/over voltage spikes on 1 dc channel; ups battery voltages or power supplies; 25/600vdc input; sensitivity 1/60vdc; 25/4000vdc impulse
01-540-6196
Electrical-electron Plug-in Unit
Remote monitor interface for dranetz 626 universal line disturbance analyzer; for programming/readout test of line disturbance data; plug-in; load rating 1
01-540-6197
Test Probe
Used on dra808 analyzer. available as refurbrished item only; clamp on current transformer probe; 0-10 amps; 20-1000 amps rms; 2 switch selectable ranges
01-540-6227
Network Analyzer
Multi-channel measurements display; large 10.4 inch color lcd; window style interface; electronic calibratione cal module
01-540-6570
Test Adapter Kit
Used on starter generator engine, observation helicopter. adapter kit, starter
01-540-7415
Electrical-electronic Test Cover
Used on c-295 transport aircraft ground equipment.
01-540-7430
Spectrum Analyzer
01-540-7528
Test Set Coupler
Used on test coupler set an/alq-126a.
01-540-7531
Test Set Coupler
Used on test coupler set an/alq-126a..
01-540-7544
Test Set Coupler
Used on test coupler set an/alq-126a.
01-540-7545
Test Set Coupler
Used on test coupler set an/alq-126a.
01-540-7548
Test Set Coupler
Used on test coupler set, an/alq-126a.
01-540-7552
Test Set Coupler
Used on test coupler set an/alq-126a.
01-540-7709
Electrical Frequency Meter
21.000" overall length 16.750" overall width microwave synthesizer 0.01 to 8 ghz rectangular surface mtg
01-540-7710
Electrical Frequency Meter
21.000" overall length 16.750" overall width microwave synthesizer 0.01 to 20 ghz. rectangular surface mtg
01-540-7952
Electronic Switch
Used on an/sqq-89(v)6 ddg69 sips ess. navy - switch, 16-port gbic L3
01-540-7955
Digital Display Indicator
Used on approved ecp a and i n3314, 15a990021. display
01-540-7975
Radio Test Set
Used on 275546-01 (09xp2) 688 icadf a(v)2/a(v)4.
01-540-8002
Electrical T Adapter Subassembly
Used on test station, electrical.
01-540-8201
Signal Generator
330.0mm overall length 284.0mm overall width
01-540-8213
Electrical Meter Subassembly
1.125" overall length model 260 silicon sensor head the S380, S370
01-540-8214
Electrical Meter Subassembly
9.250" overall length 8.500" overall width model S370 single-channel laboratory photometer add any udt photometric sensor head to the system S370,
01-540-8216
Electrical Meter Subassembly
Used on model 260 silicon sensor head. point of sensor package
01-540-8380
Fault Locating Indicator
Used on 3830-01-504-2618;sweeper,rotary,vehicle mounted. guage, falt indicator
01-540-8526
Test Probe
Used on dranetz pp4300, 656, 658, series analyzers. 12.000" overall length 12.000" overall width 1-300 amp rms current transformer; 2 us ac impulse response; porm 1 pct accuracy; max conductor size 2.000 in round jaw
01-540-9326
Signal Generator
Used on wide area augmentation (waas). waas gus sig generator
01-541-0035
Oscilloscope
10.100" overall length 6.700" overall width scopemeter the unit weights 4.4 lbs; 144 mm monochrome lcd display screen; included 4 hr ni-mh BP190 battery
01-541-0533
Radar Test Kit
Used on U-2.
01-541-0546
Voltmeter
Used on U-2. fully automatic tuned receiver; takes rf voltage
01-541-0547
Oscilloscope
Used on U-2. 2 channel; 500mhz bandwidth; 1gsa/s sample rate; includes (1) 3.5 inch 1.44 mb internal floppy drive
01-541-0549
Oscilloscope
Used on U-2. 2 channel; 500mhz bandwidth; 2gsa/s sample rate; includes (1) 3.5 inch 1.44 mb internal floppy drive
01-541-0593
Special Scale Meter
01-541-0596
Special Scale Meter
01-541-0598
Special Scale Meter
01-541-0941
Oscilloscope
Used on U-2.
01-541-0943
Oscilloscope
Used on U-2.