Electrical And Electronic Properties Measuring And Testing Instruments FSG 66 — FSC 6625

NSN
NIIN
Name
Details
01-527-9366
Magnetic Field Interferenc Probe
22.000" overall length fast battery charger included; detection isotropic; dynamic range 30 ma/m-3 a/m; data sample rate 1-24 samples per second; response time 86 msec min; calibration accuracy at cal points porm 0.5 db, absolute accuracy porm 1.0 db; linearity porm 0.5 db fs; isotropic deviation porm 0.5 db; environmental ranges 10-40 deg c; 5-95 pct relative humidity, non condensing; battery 3.6 vdc, 1400 ma-hr rechargable nicad; 20 hrs continous operations; weight 0.54 kg; key features automatic continuous zeroing, data from each axis can be viewed indiividually; fiber optic technology; for use with hi-4460
01-527-9367
Magnetic Field Interferenc Probe
22.000" overall length fast battery charger included; detection isotropic; dynamic range 300 ma/m-30 a/m; data sample rate 1-24 samples per second; response time 86 msec min; calibration accuracy at cal points porm 0.5 db, absolute accuracy porm 1.0 db; linearity porm 0.5 db; isotropic deviation porm 0.5 db; environmental ranges 10-40 deg c; 5-95 pct relative humidity, non condensing; battery 3.6 vdc, 1400 ma-hr rechargable nicad; weight 0.54 kg; key features automatic continuous zeroing, data from each axis can be viewed individually; fiber optic technology; for use with hi-4460
01-527-9368
Magnetic Field Interferenc Probe
17.000" overall length vfast battery charger
01-527-9682
Spectrum Analyzer Set
Transmission/reflection vector network analyzer 50 mhz to 20 ghz; up to 104 db ofdynamic range; 2 measurement channels; 4 display channels; frequency
01-528-0730
Spectrum Analyzer
1.5 ghz spectrum analyser
01-528-0773
Signal Generator
01-528-0879
Test Program Set
01-528-1168
Test Adapter Set
Used on ts-3098/spn,test set radar. (navy) test set adapter kit
01-528-1728
Ammeter
3.000" overall length rectangular flush mtg
01-528-1857
Electrical Field Interfere Probe
15.000" overall length frequency range 3 khz to 1 mhz; frequency response flat; sensor type active antenna; frequency sensitivity 1 db; isotropic response 0.75 db; cw overload 1000 mw/cm; peak overload 1000 w/cm; calibration frequencies 3, 10, 14, 30, 100, 300, 540, 700, 1000 khz; operating temperature M10.0 to 55.0 deg c; humidity 0.0 to 95.0 pct non condensing
01-528-1858
Infrared Transmitter
01-528-1893
Metallic Time Doma Reflectometer
90.0 ac voltage in volts and current type power reflection meter nrt
01-528-2059
Line Voltage Indicator
Used on 2320-01-519-8173.
01-528-2088
Test Electrical Panel
Used on 2320-01-519-8173.
01-528-2525
Instrument Shunt
375 amp; 375 millivolt; .1 percent accuracy; resistance .000266 ohms
01-528-2624
Electronic Digital Reado Counter
01-528-2745
Decade Resistor
4.000" overall length 17.300" overall width opt rm: rack mount; mfg name: high accuracy decade box
01-528-2750
Special Scale Meter
Used on -3 pao cart
01-528-3190
Test Lead Set
Comprehensive measurement lead
01-528-3217
Electrical Cable Test Set
900mhz maximu bandwidth; multimedia memory card; usb cable; serial computer interface cable; talk headset; cat 6 autotest in 12 seconds
01-528-3252
Electrical Test Set Subassembly
Used on fluke 5702a.
01-528-3348
Test Probe
Used on aircraft cabling,maintenance group (acmg). (navy) wire tester hand, aircraft
01-528-3460
Voltmeter
01-528-3734
Electronic Digital Reado Counter
348.3mm overall length 212.4mm overall width 150 ps universal counter; opt 012 - ultra high stability timebase; opt 030 - 3 ghz rf input ch 3
01-528-3945
Instrument Shunt
100 amp shunt; 100mv shunt. resistor with cap on side; .001 ohms; 0.1 percent accuracy
01-528-4192
Frequency Reference And Electron
01-528-4279
Radio Frequency Radiati Absorber
Used on 7519667 (53711) ty8k mod(4) periscope rcu. barrel, radar absorber
01-528-4989
Voltmeter
Used on digital meter for grn-29 mod kit. digital voltmeter accuracy porm .50 percent of reading plus 10 lsd; terminal resistance is 50.0 ohms porm 1.0 percent; 2.0 watts ; weighs less than 12 oz; high efficiency red led display, .43 in. digit height; continuous bit; dc current 50 mv span bipolar
01-528-4990
Wattmeter
Used on meter for grn-29 mod kit. accuracy porm .30 percent of reading plus 3lsd; 2.0 watts excluding external switch terminals; weighs less than 16 ounces; high efficiency red led display, w. digit height .43"; w/ external switch terminals; continuous built in test (bit) ; item is 3.12" high; 3.27" wide
01-528-4991
Voltmeter
Used on digital meter for grn-29 mod kit. accuracy porm .50 percent of reading plus 10 lsd; terminal resistance 50.0 ohms porm 1.0 percent; 2.0 watts ; weighs less than 12 ounces; high efficiency red led display, .43 inch digit height; continuous bit; ac voltage; critical for tolerance; indicator type is meter; dc voltage rating is 18 volts
01-528-4992
Ammeter
Used on digital meter mod kit for the grn-29 vrs. critical for tolerance; 5 readings per second; power requirements 2.0 watts ; weighs less than 12 ounces; high efficiency red led; normal digit height .430"; continuous bit; indicator type is meter; dc voltage rating is 18 volts
01-528-5252
Electrical-electronic Test Case
Transit case hard outside shell; designed to carry the angilent distributed network me or distributed network analyzer plus accessories
01-528-5512
Optical Time Domai Reflectometer
Used on mh-60s aft wiring system gse. mfg name-reflectometer optic
01-528-5759
Digital Data Electronic Analyzer
01-528-5771
Voltmeter
Used on digital meter for grn-29 mod kit. critical for tolerance; accuracy porm .50 percent of reading plus 10 lsd; terminal resistance is 50.0 ohms porm 1.0 percent; 2.0 watts ; weighs less than 12 oz; high efficiency red led display, .43 in digital height; continuous bit; dc voltage unipolar; indicator type is meter; dc voltage rating is 18 volts
01-528-6128
Frequency Standard
13.000" overall length 8.500" overall width
01-528-6443
Signal Generator
19.300" overall length 17.400" overall width
01-528-6449
Network Analyzer
12.100" overall length 10.100" overall width includes one data acquisition system that supports any lan or wan plug-in line interface module (lim) ; designed for dispatched
01-528-6705
Monitor Panel
Used on 6515015286662.
01-528-6750
Test Lead
Used on 6650-01-510-7502. fiber optic patch assembly diamond sc/pc connectors - type hsc-M0.66 terminated on 62.5/125/900/3000mm multimode siecor cable
01-528-6812
Voltmeter
01-528-6902
Test Lead
Used on tds200 series scope, 2 channel, 60 mhz. 100 mhz; 10x
01-528-7044
Ammeter
01-528-7084
Radio Frequency Radiati Absorber
01-528-7330
Current Sensor
Used on guided missile frigate. 2.560" overall length 1.190" overall width 10 rms; 60hz frequency; minus 20 toplus 70 degrees c operating temperature; minus 55 to plus 85 degrees c storage temperature; 150 millisecond response
01-528-7963
Electrical-electronic Test Case
Case carrying f/electronic instrument zippered, soft carrying case; includes storage compartments
01-528-8246
Voltage Deviation Monitor
Used on multifunction monitor. (navy) monitor 3, multi-function
01-528-8656
Electronic Systems Test Set
Increase test system throughput; 1/2 rack width mainframe; 2 slots; 6 different modules can be configured up to the slot capacity
01-528-9254
Electrical Test Set Subassembly
Used on network testing device. fluke network frame relay installation assistant
01-528-9255
Electrical Test Set Subassembly
Used on network testing device. fluke cable kit