rack
noise figure meter with the following requirements: freq range 10mhz to 40ghz, enr calibration range 14.0db to 16.5db, dynamic range at least 0.0db to 33.0db, bandwidth 4mhz, accuracy porm.10db (0 to 9db) porm.20db (9 to 12db) porm .4db (12 to 18db) porm .75db (18 to 21db) porm 1db (21 to 33db) , sensitivity at least -76Dbm, input frequency at least 30mhz, shall be compatible with ansi EIA-310-D standard equipment rack with 5 standard height units, weight will not exceed 40lbs, will be delivered with the following manuals: operator; maintenance and service; illustrated parts; and calibration, this item is class 3 iaw MIL-PRF-28800 except as specified within the purchase description
A81349-MIL-PRF-28800F specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) . and B97566-Ieee std 488.2-1992 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) . and C80204-Ansi EIA-310-D specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
98752-PD07CBSSSGBEC31
An instrument which measures the level of continuous noise present in amplifier and/or receiver circuits with reference to a fixed level of signal generated by a separate noise source. It is designed to measure noise levels over a wide band of frequencies including radio and video frequencies, and is normally calibrated in decibels relative to a specified r.m.s. Voltage summation across a specified impedance, or in decibels relative to a specified noise power level. if only audio frequency range, see meter, audio level.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Warner-robins air logistics center 455 byron st robins afb, ga 31098-1860
Automatic test equipment/auto test systems
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.