Serving our customers with quality and safety first.
22.200in. ⁓22-13/64"
7.000in.
17.900in.
100.0 volts and 240.0 volts
1.0 volts and 1000.0 volts
48.0 hertz and 62.0 hertz
elec systems test set APQ-180
80.000 pounds
6
single
dc source; designed to be supported by wavetek 4950 multifunction transfer standard; 8-1/2 digit accuracy; true 1 kv ac performance; opt 10 is dc voltage range porm 190 vdc without high voltage and porm 1100 vdc with high voltage; opt 20 is ac voltage range porm 190 vac without high voltage and porm 1100 vac with high voltage; IEEE-488 front panel interface
performs adjustments and calibration to E1429A/b digitizer and 1270b frequency response analyzer
similar to wavetek 4808 with OPTS20, 30 &5200 s/l as 6625-01-379-0495
2 hr warmup time; operating temp 0 to 50 deg cel; storage temp minus 40 deg to plus 70 deg cel; vacuum flourescent display; safety alarm
An item specifically designed to determine by comparison accurate input and output voltages of major electronic components. Excludes voltmeter and voltmeter, electronic.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.