Serving our customers with quality and safety first.
610.0 mm
240.0 mm
430.0 mm
100.0 volts and 240.0 volts
50.0 hertz and 60.0 hertz
LGM118A missle
30.2 kilograms
rack
0.0 to 1100vdc
4
porm 1.5 ppm plus 5 microvolts AT11V to porm 2.5 ppm plus 400 microvolts at 1100v
single
IEEE488 & RS-232C & boost interfaces; rear outputs; 4 output ranges, 0 to 11vdc, 11 to 22vdc, 22 to 275vdc, 275 to 1100vdc; output current 0 T0 60 milliamps up to 22vdc, 0 to 25 milliamps up to 1100vdc; has program module for presetting for test sequences; 40 character ALPHA-Numeric vacuum fluorescent display; power consumption 84 watts in standby, 145 watts
option mm is rackmounting kits, r/n M08-205-600 and M00-280-610
An item specifically designed to determine by comparison accurate input and output voltages of major electronic components. Excludes voltmeter and voltmeter, electronic.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.