NSN 6625-01-304-8860 NIIN 013048860 — Voltmeter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-01-304-8860
6625013048860
Description:
VOLTMETER
NSN Assigned:
28-JUL-89
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-01-304-8860 Specification Set by the OEM (see RNCC code 3)

Circuit Current For Which Designed AACT:

ac

Dielectric Withstanding Voltage In Volts AAPB:

3000.0

Overall Length ABHP:

5.630in. ⁓5-41/64"

Overall Height ABKW:

1.890in.

Overall Width ABMK:

3.780in.

Frequency Rating ACZB:

1000.0 hertz and 2000.0 hertz

Environmental Protection ADZC:

airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant

Furnished Items And Quantity AKYN:

seal 1; STRAP1

Indicator Type AMKD:

digital display

Installation Design AMQY:

panel

Sensitivity Rating ANTG:

500.0 millivolts

Dial Scale Marking Color APMM:

white single indicator single range

Meter Depth Behind Mounting Flange APST:

5.250in.

Meter Body Width Behind Mounting Flange APSY:

3.620in.

Background Color AQFY:

black single indicator single range

Power Source AWZJ:

external

Mounting Facility Type And Quantity AXHR:

1 bracket

Display Type BFQN:

light emitting diode

Display Digit Quantity BFQP:

4-1/2

Measurement Range BHMW:

+0.0/+500.0 millivolts, ac single indicator single range

Scale Selection Method BLSB:

terminal

Meter Body Height Behind Mounting Flange BMNG:

1.770in.

Features Provided CBBL:

overranging

Accuracy Rating CTPT:

porm 1 pct of reading plus 1 digit single indicator single range

Display Color CTQH:

red single indicator single range

Circuit Attachment Method And Quantity CTTD:

1 printed circuit

Operating Voltage Rating In Volts CTWN:

115.0 ac

Phase FAAZ:

single

Special Features FEAT:

ruggedized; automatic zero; rms calibration

Special Markings MARK:

on back, one side marked + and other side marked -

Material MATT:

plastic

Nuclear Hardness Critical Feature NHCF:

nonhardened

Surface Treatment SFTT:

paint

Style Designator STYL:

rectangular flush mtg

Supplementary Features SUPP:

100 ko min impedance

Fsc Application Data ZZZV:

test set, elect. equip.

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
604AS1053-1
Cage Code:
30003
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
233-3-D1
Cage Code:
24514
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
16449
FIIG:
A310A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR RECTANGULAR FLUSH MTG style nsn 6625-01-304-8860
STYLE DESIGNATOR RECTANGULAR FLUSH MTG style nsn 6625-01-304-8860

Definition Definition of approved item name (AIN): "VOLTMETER"

An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-01-304-8860 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.