Serving our customers with quality and safety first.
400.0 hertz
surveillance/electron countermeasures subsystem (ecms) ; an/ALQ-161
single item w/housing
tests and fault isolates regulated power supply T207 p/n 436759-9 of the band 4 transmitter aft & regulated power supply board T104 p/n 436744-2/-3 of band 4 transmitter
ac input 389 volts; used in conjunction with tek oscope 2465dvs; fluke digital multimeter 8840a; and eaton 488102-3 400 hz test set
three
used to test cable assembly p/n 087-013976-001
B-1B aircraft
A test set primarily designed for use in making examinations of electrical cables. can be used for locating shorts, crosses, and grounds in electrical cables. this would also permit locating high resistant faults. see also test set (1), power-special purpose electrical cable assembly. excludes reflectometer, metallic time domain.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.