NSN 6625-01-236-6388 NIIN 012366388 — Oscilloscope

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-01-236-6388
6625012366388
Description:
OSCILLOSCOPE
NSN Assigned:
20-JUL-86
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-01-236-6388 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

17.500in. ⁓17-1/2"

Overall Height ABKW:

5.400in.

Overall Width ABMK:

13.200in.

Current Type ACDC:

ac or dc

Frequency Rating ACZB:

40.0 hertz and 440.0 hertz

End Item Identification AGAV:

5825-00-128-3195, beacon transponder, an/TRN-26

Voltage Rating AMSE:

100.0 volts and 220.0 volts and 220.0 volts and 240.0 volts

Beam Quantity ATES:

1

Graduation Interval AWEC:

graduated in. v/div on Y-Axis; graduated in. time/div on X-Axis

Sweep Circuits BGQL:

included

Generator Driven Feature BGQM:

included

Sweep Circuit Type BGQN:

horizontal and vertical

Sweep Frequency Range BGQP:

+0.0/+100.0 megahertz

Single Trigger Sweep Duration BGQQ:

0.00005 microseconds and 500000.0 microseconds

Trigger Sweep Voltage Amplitude Rating BGRZ:

100.0 megavolts and 300.0 megavolts

Trigger Sweep Polarity Switch BGSB:

included

Trigger Sweep Marker Intervals BGSC:

0.5 second and 50 nanosecond

Expanded Sweep BGSD:

provided

Amplifier Deflection Sensitivity Provision BHDD:

not provided

Input Intensity Modulation Feature BHDH:

provided

Plate Direct Connection Deflection Sensitivity Provision BHDL:

provided

Frequency Response Rating BHDP:

provided

Amplifier Input Impedance Rating Provision BHDT:

not provided

Calibrated Screen Scale BHFF:

included

Trace Storage Tube BHFH:

included

Camera Recording Device Accommodation BHFT:

not provided

Phase FAAZ:

single

Special Features FEAT:

transit case provided

Supplementary Features SUPP:

oper. alt. 15000.0 ft.; oper.TEMPM10.0 to P55.0 deg. c; P31 phosphor standard; dc voltage rating 20.0-32.0

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
119235-101
Cage Code:
19156
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
SB
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00357
FIIG:
T320-G
Concept No.:
App. Key:
GA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "OSCILLOSCOPE"

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
25.0 X 19.0 X 16.5
Paclk Weight:
30.2000lbs
Item Weight:
15.0000lbs
Item Dim:
017501050068
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
4294967295
OPI:
M
SPI No.:
F000003XE7
SPI Rev.:
SPC Mkg:
17
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 17

Reusable container.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-01-236-6388 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
FHZ
SOS:
MMAC:
IM
MCC:
Source of Supply (SOS) FHZ

Oklahoma city air logistics center 3001 staff drive tinker afb, ok 73145-3303

Material Management (MMAC) IM

Ground navigation aids navaids

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.