dc
2.500in. ⁓2-1/2"
2.562in.
3.939in.
80 single indicator all ranges
0.625in.
3.000in.
dial w/pointer
panel
two hole/stud
1.0 milliamperes
black single indicator all ranges
-2.0/+2.0 at full scale single indicator all ranges
1.311in.
2.125in.
moving coil, permanent magnet
white single indicator all ranges
red single indicator all ranges
external
2 threaded stud
nonlinear single indicator all ranges
+0.0/+30.0 volts, dc single indicator 1st range
0.125in.
2 threaded stud
rf drive level; normal ac line reading from 25 to 28 first range; 86 to 96 second range
plastic
nonhardened
rectangular flush mtg
An instrument with two or more different scales measuring different quantities, usually on a single calibrated dial or digital readout display. it is intended for visually monitoring an operation. the meter must be permanently connected into an appropriate electronic circuit. excludes: ammeter; voltmeter; wattmeter and meter, electrical frequency.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
To be assigned to an item containing embedded adpe that meets one or more of the definitions for codes 1 through 6.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.