NSN 6625-01-126-6936 NIIN 011266936 — Voltmeter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-01-126-6936
6625011266936
Description:
VOLTMETER
NSN Assigned:
15-FEB-82
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-01-126-6936 Specification Set by the OEM (see RNCC code 3)

Circuit Current For Which Designed AACT:

dc

Dielectric Withstanding Voltage In Volts AAPB:

2600.0

Overall Length ABHP:

5.500in. ⁓5-1/2"

Center To Center Distance Between Mounting Facilities Parallel To Length ABKQ:

3.438in.

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

3.469in.

Overall Height ABKW:

4.281in.

Overall Width ABMK:

4.250in.

Scale Division Quantity ABWG:

50 single indicator single range

Indicator Type AMKD:

dial w/pointer

Installation Design AMQY:

panel

Mounting Arrangement Style ANRL:

four hole/stud rectangular/square

Dial Scale Marking Color APMM:

black single indicator single range

Accuracy In Percent APPN:

-1.0/+1.0 at full scale single indicator single range

Meter Depth Behind Mounting Flange APST:

3.594in.

Meter Body Diameter Behind Mounting Flange APSW:

4.000in.

Movement Type AQEC:

moving coil, permanent magnet

Background Color AQFY:

white single indicator single range

Pointer Color ASSS:

black single indicator single range

Mounting Facility Type And Quantity AXHR:

4 threaded stud

Scale Graduation Type BHDC:

linear single indicator single range

Measurement Range BHMW:

+0.0/+50.0 volts, dc single indicator single range

Mounting Stud Diameter BLKZ:

0.234in.

Circuit Attachment Method And Quantity CTTD:

2 threaded stud

Operating Voltage Rating In Volts CTWN:

50.0 dc

Material MATT:

plastic and copper alloy

Nuclear Hardness Critical Feature NHCF:

nonhardened

Surface Treatment SFTT:

enamel

Style Designator STYL:

rectangular flush mtg

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
MR49W050DCVVH
Cage Code:
81349
RNCC:
2
RNVC:
2
DAC:
6
RNAAC:
XG
Status:
A
MSDS:
SADC:
Part Number:
MIL-M-16034
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
6
RNAAC:
XG
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
16449
FIIG:
A310A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR RECTANGULAR FLUSH MTG style nsn 6625-01-126-6936
STYLE DESIGNATOR RECTANGULAR FLUSH MTG style nsn 6625-01-126-6936
MOUNTING ARRANGEMENT STYLE FOUR HOLE/STUD RECTANGULAR/SQUARE style nsn 6625-01-126-6936

Definition Definition of approved item name (AIN): "VOLTMETER"

An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

6625-01-126-6936 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
9
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

ADPE 9

To be assigned to an item containing embedded adpe that meets one or more of the definitions for codes 1 through 6.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.