NSN 6625-01-058-9545 NIIN 010589545 — Oscilloscope

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-01-058-9545
6625010589545
Description:
OSCILLOSCOPE
NSN Assigned:
05-APR-78
DEMIL:
NO
Shelf Life:
N/A
UOM:
No qup EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-01-058-9545 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

24.700in. ⁓24-45/64"

Overall Height ABKW:

5.250in.

Overall Width ABMK:

19.000in.

Current Type ACDC:

ac

Frequency Rating ACZB:

50.0 hertz and 400.0 hertz

End Item Identification AGAV:

4920-01-010-1525Test bench infrared

Accessory Components And Quantity AKYD:

cable assembly rf 2; filter, light, crt 2; hardware kit, electronic equipment 1; guide set, rackmount 1

Voltage Rating AMSE:

110.0 volts and 240.0 volts

Beam Quantity ATES:

1

Graduation Interval AWEC:

graduated in v/cm on both axis; graduated in sec/cm on x axis

Mounting Method AXGY:

cabinet w/complete hardware for rack

Accuracy Range In Percent BDJD:

-2.0/+2.0

Screen Size BGQK:

8 by 10 centimeters

Sweep Circuits BGQL:

not included

Expanded Sweep BGSD:

not provided

Amplifier Deflection Sensitivity Provision BHDD:

not provided

Vertical Deflection Sensitivity Voltage Rating BHDF:

3.1 volts rms per centimeter

Horizontal Deflection Sensitivity Voltage Rating BHDG:

7.8 volts any acceptable minor

Input Intensity Modulation Feature BHDH:

not provided

Visual Modulation Sensitivity Voltage Rating BHDJ:

200.0 megavolts

Visual Blanking Sensitivity Voltage Rating BHDK:

2.0 volts

Plate Direct Connection Deflection Sensitivity Provision BHDL:

provided

Direct Connection Vertical Deflection Sensitivity Voltage Rating BHDM:

3.1 volts peak minor

Direct Connection Horizontal Deflection Sensitivity Voltage Rating BHDN:

7.8 volts rms per centimeter

Frequency Response Rating BHDP:

provided

X-axis Frequency Response Rating BHDQ:

2.0 megahertz

Y-axis Frequency Response Rating BHDR:

100.0 megahertz

Z-axis Frequency Response Rating BHDS:

10.0 megahertz

Amplifier Input Impedance Rating Provision BHDT:

provided

X-axis Input Impedance Rating BHDW:

1.0 megohms

Y-axis Input Impedance Rating BHDX:

1.0 megohms

Z-axis Input Impedance Rating BHDY:

5000.0 ohms

Calibrating Peak To Peak Amplitude BHFB:

1.0 volts

Calibrated Screen Scale BHFF:

included

Trace Storage Tube BHFH:

not included

Plug In Unit Function And Quantity BHFS:

vertical amplifiers 2; dual time base amplifier 1

Camera Recording Device Accommodation BHFT:

provided

Phase FAAZ:

single

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
R7603 OPT1-3-4
Cage Code:
80009
RNCC:
3
RNVC:
2
DAC:
3
RNAAC:
KE
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00357
FIIG:
T320-G
Concept No.:
App. Key:
GA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "OSCILLOSCOPE"

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
41.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
03
LVL_A:
E
LVL_B:
Q
LVL_C:
Q
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 03

Method 50.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-01-058-9545 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
N
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality N

The item does not have a critical feature such as tolerance, fit restrictions or application. nuclear hardness properties have not been determined (not valid for input).

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
NRP
SOS:
UZ
MMAC:
MCC:
Source of Supply (SOS) NRP

Navicp-erp 700 robbins avenue philadelphia, pa 19111-5099

Special Material (SMIC) UZ

Aam-60(v) test set

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.