Serving our customers with quality and safety first.
15.500in.
16.750in.
115.0 volts and 26.0 volts
400.0 hertz
test plug assembly; cable assembly
1 and 1
consolidated airborne systems
1727 part no.
test set, synchro instruments, field
type no. TTU-23/e
alternate operating
not included
aluminum carrying case
multiple item w/carrying case
accuracy of angular motion, detection of overloads, measurement of voltage
autosyn control transformer, rotoroutput voltage 22.4 v angular accuracyporm 4 min; autosyn transmitter, rotor excitation 26 v, 400 cps single phase stator output voltage, 11.8 v angular accuracy porm 4 minutes; locked autosyn, rotor excitation 26v, 400 cps single phase stator output voltage 11.8v angular accuracy porm 10 minutes max
single
9.500in.
test sets, synchro, except specially designed
A test set primarily designed for use in making examinations of the operation of synchros, such as measuring the accuracy of angular motion. See also transformer, synchro overload.
Indicates that the item represented by the nsn in the input/output header is replaced by the preferred item represented by the nsn in the segment h. This code indicates a one-way substitution. Must be used in combination with phrase code 7 when pica loa is 01, 02, 06, 22, or 23.
OOU: Order of Use. Three position alpha code denoting the interchangeability and substitutability (I&S) relationship of a national stock number within a service/agency I&S family.
JTC: Jump to Code. Three position alpha code that denotes an exception to the normal sequence to be followed in the attrition of items within an interchangeability and substitutability (I&S) family.
Phrase Code: A one position code assigned to a phrase used in the management data list to denote changes and/or relationships between national stock numbers and reference data.
Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.
Method 50 reusable container.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Precious metal content is unknown
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Warner-robins air logistics center 455 byron st robins afb, ga 31098-1860
Automatic test equipment/auto test systems
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.