NSN 6625-00-837-0605 NIIN 008370605 — Electrical Frequency Meter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-00-837-0605
6625008370605
Description:
METER,ELECTRICAL FREQUENCY
NSN Assigned:
12-DEC-66
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-00-837-0605 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

2.050in. ⁓2-1/16"

Mounting Stud Length ADAG:

0.375in. and 0.625in.

Overall Diameter ADAV:

3.510in. ⁓3-33/64"

Mounting Bolt Circle Diameter AFFL:

3.160in.

Installation Design AMQY:

panel

Mounting Arrangement Style ANRL:

three hole/stud bolt circle

Frequency Response Range ANSY:

+48.000/+62.000 hertz

Dial Scale Marking Color APMM:

black single indicator single range

Accuracy In Percent APPN:

-2.0/+2.0 at full scale single indicator single range

Meter Depth Behind Mounting Flange APST:

1.660in.

Meter Body Diameter Behind Mounting Flange APSW:

2.800in.

Background Color AQFY:

white single indicator single range

Mounting Facility Type And Quantity AXHR:

3 flange

Measurement Range BHMW:

+48.0/+62.0 hertz single indicator single range

Scale Selection Method BLSB:

terminal

Features Provided CBBL:

magnetic shield and zero adjuster

Circuit Attachment Method And Quantity CTTD:

2 threaded stud

Special Features FEAT:

terminal no. 4-40 thd 0.340 in. lg meter scale region between 53 and 57 hertz unmarked

Special Markings MARK:

blue line at 50 hertz, red line at 60 hertz

Style Designator STYL:

round flush mtg

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
13212E1374
Cage Code:
97403
RNCC:
1
RNVC:
2
DAC:
1
RNAAC:
CT
Status:
A
MSDS:
SADC:
Part Number:
253163-1539
Cage Code:
65092
RNCC:
3
RNVC:
9
DAC:
5
RNAAC:
CT
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
16454
FIIG:
A310A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR ROUND FLUSH MTG style nsn 6625-00-837-0605
MOUNTING ARRANGEMENT STYLE THREE HOLE/STUD BOLT CIRCLE style nsn 6625-00-837-0605

Definition Definition of approved item name (AIN): "METER,ELECTRICAL FREQUENCY"

An instrument which measures the rate of regularly recurring variations in an electric current or voltage and is usually calibrated in hertz (cycles per second or cps). The value may be expressed by means of a pointer and calibrated dial vibrating reed or a digital read out display. For instruments which measure radio frequencies, see calibrator, frequency; and wavementer. excludes: counter electronic digital.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
2.8000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
6
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

LVL C Code (LVL_C) 6

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 3.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-00-837-0605 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.