Serving our customers with quality and safety first.
24.000in.
40.000in.
115.0 volts
60.0 hertz
operating
single item w/housing
circuit analyzer
single
AA-1.3
unit is a bench item which simplifies the location and identification of wiring flaws, it tests wiring harnesses, coaxial cables, and relay boxes for circuit continuity, shorts, high voltage leakage and operation; input rating 200 circuits ; resistance range 0 to 500 ohms (ohmmeter) , 0 to 1 megohm at 29 vdc (short) , and 0 to 200 megohm at 500 vdc (short) ; meter data from RX-1 to RX-10 in 8 steps; accuracy +/- 3% (ohmmeter)
used to check the Q-2C aerial target wiring harnesses, coaxial cables, and relay boxes for circuit continuity, shorts, high voltage leakage and operation
24.000in.
70-04-01
DIT-Mco, inc. commercial data
interchangeable with 6625-00-820-5307
the circuit analyzer provides test voltages of 28 vdc and 500 vdc to the test panel and the harness test panel for checking the harnesses and varioous components of the Q-2C aeriel target
A test set designed for use in making examinations of power electrical cable assemblies or special purpose electrical cable assemblies. Excludes test set, electrical cable.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.