NSN 6625-00-649-0075 NIIN 006490075 — Insulation Breakdown Test Set

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-00-649-0075
6625006490075
Description:
TEST SET,INSULATION BREAKDOWN
NSN Assigned:
01-JAN-63
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-00-649-0075 Specification Set by the OEM (see RNCC code 3)

Wire Termination Type ABCC:

prod

Overall Length ABHP:

22.000in. ⁓22-1/64"

Overall Height ABKW:

11.000in.

Overall Width ABMK:

15.000in.

Ac Voltage Rating ACYN:

110.0 volts

Frequency Rating ACZB:

60.000 hertz

Wire Lead Length AFSC:

72.000in.

Installation Design AMQY:

portable

Output Current Type ANPN:

ac

Meter Type ANTH:

voltmeter

Meter Quantity ANTJ:

1

Scale Range APSK:

+0.0/+2.5 kilovolts

Output Frequency Rating APTS:

60.000 hertz

Output Voltage Rating AQYB:

2.500 kilovolts

Leakage Indicator Type AQYK:

lamp

Test Lead Quantity AQYL:

2

Phase FAAZ:

single

Functional Classification FCLS:

AA-8.14

Functional Description FTLD:

provides high voltage necessary for insulation breakdown tests of electrical instruments, containing CAPACITOR-Type circuits, and other equipment. current flow is limited and controllable

Entry Date NTRD:

70-04-01

Reference Data And Literature RDAL:

t.o. 33A1-12-114-11, operation and service instructions

Relationship To Similar Equipment RTSE:

df) when exhausted use 6625-00-802-9445

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
13700-1B
Cage Code:
55974
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
SB
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
16408
FIIG:
T228-C
Concept No.:
1
App. Key:
CC
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "TEST SET,INSULATION BREAKDOWN"

A test set primarily designed to detect and indicate insulation breakdown in electric motors, transformers, and the like, at specific test voltages. See also test set, armature; and ohmmeter.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
3,600.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
F000004I87
SPI Rev.:
SPC Mkg:
19
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 19

Method 50 reusable container.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-00-649-0075 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.