NSN 6625-00-635-4289 NIIN 006354289 — Multiple Scale Meter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-00-635-4289
6625006354289
Description:
METER,MULTIPLE SCALE
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
No qup EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-00-635-4289 Specification Set by the OEM (see RNCC code 3)

Circuit Current For Which Designed AACT:

dc

Dielectric Withstanding Voltage In Volts AAPB:

3000.0

Overall Length ABHP:

1.971in. ⁓1-63/64"

Mounting Hole Diameter ABTB:

0.122in.

Scale Division Quantity ABWG:

40 single indicator 2nd range

Overall Diameter ADAV:

2.678in. ⁓2-11/16"

Environmental Protection ADZC:

airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant

Mounting Bolt Circle Diameter AFFL:

2.440in.

Furnished Items And Quantity AKYN:

nut 3; lockwasher 3; seal 1; shunt wire 1

Indicator Type AMKD:

dial w/pointer

Installation Design AMQY:

panel

Mounting Arrangement Style ANRL:

three hole/stud bolt circle

Sensitivity Rating ANTG:

200.0 microamperes

Dial Scale Marking Color APMM:

black single indicator all ranges

Accuracy In Percent APPN:

-2.0/+2.0 at full scale single indicator all ranges

Meter Depth Behind Mounting Flange APST:

1.155in.

Meter Body Diameter Behind Mounting Flange APSW:

2.164in.

Movement Type AQEC:

moving iron vane

Background Color AQFY:

white single indicator all ranges

Pointer Color ASSS:

black single indicator all ranges

Power Source AWZJ:

external

Mounting Facility Type And Quantity AXHR:

3 screw and 3 unthreaded hole

Scale Graduation Type BHDC:

nonlinear single indicator 1st range

Measurement Range BHMW:

-10.0/+3.0 decibels above or below one milliwatt single indicator 1st range

Scale Selection Method BLSB:

terminal

Features Provided CBBL:

magnetic shield and zero adjuster

Movement Suspension Method CTQL:

jewel pivot base

Circuit Attachment Method And Quantity CTTD:

2 eyelet w/tab

Special Features FEAT:

ruggedized

Special Markings MARK:

on front, average power; on back, sealed do not open

Material MATT:

steel

Nuclear Hardness Critical Feature NHCF:

nonhardened

Surface Treatment SFTT:

paint

Special Test Features SPCL:

complies with MIL-M-10304

Style Designator STYL:

round flush mtg

Fsc Application Data ZZZV:

test set, elect. equip.

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
C721027REVSUBLETTERC
Cage Code:
56232
RNCC:
3
RNVC:
2
DAC:
6
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
C721027REVC
Cage Code:
56232
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
62222
FIIG:
A310A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR ROUND FLUSH MTG style nsn 6625-00-635-4289
MOUNTING ARRANGEMENT STYLE THREE HOLE/STUD BOLT CIRCLE style nsn 6625-00-635-4289

Definition Definition of approved item name (AIN): "METER,MULTIPLE SCALE"

An instrument with two or more different scales measuring different quantities, usually on a single calibrated dial or digital readout display. it is intended for visually monitoring an operation. the meter must be permanently connected into an appropriate electronic circuit. excludes: ammeter; voltmeter; wattmeter and meter, electrical frequency.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.5000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
U

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-00-635-4289 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.