NSN 6625-00-255-0186 NIIN 002550186 — Wavemeter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-00-255-0186
6625002550186
Description:
WAVEMETER
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-00-255-0186 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

8.000in. ⁓8-1/64"

Overall Height ABKW:

5.000in.

Overall Width ABMK:

6.000in.

Case Material ADTV:

aluminum

Internal Battery Accommodation ALSF:

not included

Instrument Calibration Range BDHS:

5850 mc to 7050 mc range

Calibration Accuracy Rating BDHW:

porm 0.03 pct accuracy

Special Features FEAT:

hermetically sealed cavity; frequency stability 2 parts in 1 million per deg 0

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
555B
Cage Code:
9N770
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
TU
Status:
A
MSDS:
SADC:
Part Number:
555B
Cage Code:
0C9D4
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TU
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00783
FIIG:
T134-H
Concept No.:
App. Key:
HA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "WAVEMETER"

An item for the determination of the electrical wavelength or frequency being generated by an electronic equipment such as a radio transmitter. It may be placed in the radiation field of the equipment, thereby operating on the "absorption" principle, or connected into a transmission line or waveguide run between the equipment and a component such as an antenna, thereby operating on the tuned cavity resonance principle. It includes inscriptions from which the wavelength or frequency can be determined directly, or by reference to an associated calibration curve or tabulation. The wavemeter operates in accordance with its design function only when the equipment under measurement is operating. For items, such as grid dip meters, that determine the same information when the equipment under measurement is not operating, see frequency meter.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
1,700.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
F000004E52
SPI Rev.:
SPC Mkg:
19
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 19

Method 50 reusable container.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-00-255-0186 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.