NSN 6625-00-229-7092 NIIN 002297092 — Modulation Meter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-00-229-7092
6625002297092
Description:
METER,MODULATION
NSN Assigned:
12-FEB-69
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-00-229-7092 Specification Set by the OEM (see RNCC code 3)

Circuit Current For Which Designed AACT:

dc

Dielectric Withstanding Voltage In Volts AAPB:

3000.0

Overall Length ABHP:

2.000in. ⁓2-1/64"

Mounting Hole Diameter ABTB:

0.125in.

Scale Division Quantity ABWG:

20 single indicator single range

Overall Diameter ADAV:

2.695in. ⁓2-45/64"

Environmental Protection ADZC:

cold resistant and heat resistant and shock resistant and submersible and vibration resistant and watertight

Mounting Bolt Circle Diameter AFFL:

2.440in.

Furnished Items And Quantity AKYN:

nut 7; washer 7

Indicator Type AMKD:

dial w/pointer

Installation Design AMQY:

panel

Mounting Arrangement Style ANRL:

three hole/stud bolt circle

Dial Scale Marking Color APMM:

white single indicator single range

Accuracy In Percent APPN:

-1.0/+1.0 at full scale single indicator single range

Unable To Decode APSN:

unable to decode or unable to decode

Meter Depth Behind Mounting Flange APST:

1.600in.

Meter Body Diameter Behind Mounting Flange APSW:

2.210in.

Movement Type AQEC:

moving coil, permanent magnet

Background Color AQFY:

black single indicator single range

Pointer Color ASSS:

white single indicator single range

Mounting Facility Type And Quantity AXHR:

3 unthreaded hole

Scale Graduation Type BHDC:

linear single indicator single range

Measurement Range BHMW:

-100.0/+100.0 percent deviation single indicator single range

Features Provided CBBL:

electrostatic shield and luminous scale marking and magnetic shield and zero adjuster

Movement Suspension Method CTQL:

jewel pivot base

Circuit Attachment Method And Quantity CTTD:

2 solder lug and 2 threaded stud

Special Features FEAT:

ruggedized

Material MATT:

steel corrosion resisting

Nuclear Hardness Critical Feature NHCF:

nonhardened

Surface Treatment SFTT:

enamel semigloss

Special Test Features SPCL:

conforms to MIL-M-10304/5 type MR26B5T5Dcuar; complies with ansi specification C-39.1

Style Designator STYL:

round flush mtg

Fsc Application Data ZZZV:

test set, elect. equip.

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
HS2Z
Cage Code:
33005
RNCC:
5
RNVC:
1
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
265
Cage Code:
15309
RNCC:
5
RNVC:
1
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
22222
Cage Code:
13923
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
16446
FIIG:
A310A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR ROUND FLUSH MTG style nsn 6625-00-229-7092
MOUNTING ARRANGEMENT STYLE THREE HOLE/STUD BOLT CIRCLE style nsn 6625-00-229-7092

Definition Definition of approved item name (AIN): "METER,MODULATION"

An instrument which measures the relative amount of modulation present in an electrical wave form and is usually calibrated in percent or kilohertz (kilocycles) deviation. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

6625-00-229-7092 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.