NSN 6625-00-170-5896 NIIN 001705896 — Oscilloscope

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-00-170-5896
6625001705896
Description:
OSCILLOSCOPE
NSN Assigned:
14-FEB-73
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
1 EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-00-170-5896 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

18.812in. ⁓18-13/16"

Overall Height ABKW:

9.703in.

Overall Width ABMK:

14.688in.

Current Type ACDC:

ac

Frequency Rating ACZB:

48.0 hertz and 440.0 hertz

Accessory Components And Quantity AKYD:

filter 1; cover 1; probe 2; power cord 1; manuel 1

Voltage Rating AMSE:

115.0 volts and 230.0 volts

Beam Quantity ATES:

1

Graduation Interval AWEC:

graduated in v/cm both axis

Mounting Method AXGY:

table

Accuracy Range In Percent BDJD:

-1.0/+1.0

Screen Size BGQK:

6.000 by 10.000 cm

Sweep Circuits BGQL:

included

Sweep Circuit Type BGQN:

horizontal and vertical

Sweep Frequency Range BGQP:

+0.0/+150.0 megahertz

Trigger Sweep Voltage Amplitude Rating BGRZ:

50.0 millivolts and 200.0 millivolts

Amplifier Deflection Sensitivity Provision BHDD:

provided

Vertical Deflection Sensitivity Voltage Rating BHDF:

5.0 millivolts peak to peak per centimeter and 5.0 volts peak to peak per centimeter

Horizontal Deflection Sensitivity Voltage Rating BHDG:

5.0 millivolts cw megahertz and 5.0 volts peak megahertz

Input Intensity Modulation Feature BHDH:

provided

Visual Blanking Sensitivity Voltage Rating BHDK:

6.0 volts

Plate Direct Connection Deflection Sensitivity Provision BHDL:

not provided

Amplifier Input Impedance Rating Provision BHDT:

provided

X-axis Input Impedance Rating BHDW:

1.0 megohms

Y-axis Input Impedance Rating BHDX:

1.0 megohms

Z-axis Input Impedance Rating BHDY:

1.0 megohms

Amplitude Calibrating Voltage Waveform BHDZ:

square wave

Calibrating Peak To Peak Amplitude BHFB:

1.0 volts

Calibrated Screen Scale BHFF:

included

Trace Storage Tube BHFH:

not included

Camera Recording Device Accommodation BHFT:

not provided

Phase FAAZ:

single

Functional Classification FCLS:

AA-3.1

Functional Description FTLD:

dual channel, portable; frequency range 0-150 mhz; modular construction; no holes or fans are required for ventilation; has a fully calibrated crt w/ sharp traces, crt is scale illuminated

Entry Date NTRD:

73-12-15

Reference Data And Literature RDAL:

HEWLETT-Packard oper & service manual; t.o. 33A1-13-446-1, -4

Relationship To Similar Equipment RTSE:

interchangeable w/ 6625001275729 & 6625001679863

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
1710A-H50
Cage Code:
1LQK8
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1710A0PTH50
Cage Code:
28480
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
SB
Status:
A
MSDS:
SADC:
Part Number:
1710A-H50
Cage Code:
1LQK8
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1710A0PTH50
Cage Code:
28480
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
SB
Status:
A
MSDS:
SADC:
Part Number:
1710A-H50
Cage Code:
1LQK8
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1710A0PTH50
Cage Code:
28480
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
SB
Status:
A
MSDS:
SADC:
Part Number:
1710A-H50
Cage Code:
1LQK8
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1710A0PTH50
Cage Code:
28480
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
SB
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00357
FIIG:
T320-G
Concept No.:
App. Key:
GA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "OSCILLOSCOPE"

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
32.5 X 26.5 X 16.5
Paclk Weight:
55.7000lbs
Item Weight:
0.0000lbs
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
F000004I89
SPI Rev.:
SPC Mkg:
19
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 19

Method 50 reusable container.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6625-00-170-5896 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
FLZ
SOS:
MMAC:
RH
MCC:
Source of Supply (SOS) FLZ

Warner-robins air logistics center 455 byron st robins afb, ga 31098-1860

Material Management (MMAC) RH

Automatic test equipment/auto test systems

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.