NSN 6625-00-089-5687 NIIN 000895687 — Oscilloscope

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6625-00-089-5687
6625000895687
Description:
OSCILLOSCOPE
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6625-00-089-5687 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

22.637in. ⁓22-41/64"

Overall Height ABKW:

14.567in.

Overall Width ABMK:

21.260in.

Current Type ACDC:

ac

Frequency Rating ACZB:

48.0 hertz and 61.0 hertz

Accessory Components And Quantity AKYD:

cable assy, power 1, cable assy, rf 1, graticycle 1, probes 2

Voltage Rating AMSE:

115.0 volts and 125.0 volts and 220.0 volts and 235.0 volts

Beam Quantity ATES:

2

Mounting Method AXGY:

table

Screen Size BGQK:

14 in.

Sweep Circuits BGQL:

included

Sweep Circuit Type BGQN:

vertical and horizontal

Sweep Frequency Range BGQP:

+0.05/+20.00 kilohertz

Expanded Sweep BGSD:

provided

Input Intensity Modulation Feature BHDH:

not provided

Plate Direct Connection Deflection Sensitivity Provision BHDL:

not provided

Frequency Response Rating BHDP:

not provided

Amplifier Input Impedance Rating Provision BHDT:

provided

Y-axis Input Impedance Rating BHDX:

500.0 megohms

Calibrated Screen Scale BHFF:

not included

Trace Storage Tube BHFH:

not included

Camera Recording Device Accommodation BHFT:

not provided

Phase FAAZ:

single

Functional Classification FCLS:

AA-3.3

Functional Description FTLD:

affords simultaneous display of 2 separate quantities as a function of frequency over a wide band, in form of continuous curves

Entry Date NTRD:

70-04-01

Reference Data And Literature RDAL:

rhode & schwarz r/n swob bn 4244/75; t.o. 33K3-4-1/679

Relationship To Similar Equipment RTSE:

similar to rhode & schwarz (94346) type swob 4244/60 which have a characteristic impedance of 50 & 60 ohms respectively

Fsc Application Data ZZZV:

oscilloscope, except specially designed

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
MIL-HDBK-300(PME)
Cage Code:
1HBK1
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
SW0BBN4244-75
Cage Code:
D0894
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00357
FIIG:
T320-G
Concept No.:
App. Key:
GA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "OSCILLOSCOPE"

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

6625-00-089-5687 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.