NSN 6620-01-174-8150 NIIN 011748150 — Pressure Dial Indicating Gage

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6620-01-174-8150
6620011748150
Description:
GAGE,PRESSURE,DIAL INDICATING
NSN Assigned:
23-MAR-84
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6620-01-174-8150 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

5.690in. ⁓5-45/64"

Overall Height ABKW:

4.420in.

Overall Width ABMK:

4.420in.

Overall Diameter ADAV:

3.960in. ⁓3-31/32"

Graduation Unit ANBJ:

10.0 degrees

Actuation Type APCM:

magnetic

Adjustability APCS:

nonadjustable

Scale Range APSK:

+0.0/+150.0 deg celsius

Scale Name AQFZ:

temperature

Dial Size ARCH:

3.375in. dia

Pointer Marking ASPE:

cw

Pointer Color ASSS:

black

Pointer Type ASST:

indicating

Scale Marking ASTW:

temperature gage

Scale Type ATEQ:

enclosed glass

Scale Smallest Increment AWAG:

10.0 deg celsius

Scale Accuracy BGKS:

1.5 pct

Actuating Element Material BGKY:

metal

Scale Inscription/background Color BGKZ:

black figures, whites background

Scale Length BGLB:

10.0 mm

Scale Name For Which Pointer Is Designed BGLC:

temperature

Special Features FEAT:

use on generator set, diesel engine, NSN6115-00-450-5881

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
80-7682
Cage Code:
30554
RNCC:
1
RNVC:
2
DAC:
1
RNAAC:
AJ
Status:
A
MSDS:
SADC:
Part Number:
1-66842TYPEKX241
Cage Code:
88416
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
AJ
Status:
A
MSDS:
SADC:
Part Number:
403471-001
Cage Code:
93742
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
AJ
Status:
A
MSDS:
SADC:
Part Number:
1-68285TYPE KX-241
Cage Code:
88416
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
AJ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
07428
FIIG:
T179-B
Concept No.:
App. Key:
BA
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "GAGE,PRESSURE,DIAL INDICATING"

An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. it may include a temperature equivalent scale. for items that do not have an internal pressure sensitive element see indicator, pressure.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
4.4000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
05
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 05

Delicate instrument.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6620-01-174-8150 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.