Serving our customers with quality and safety first.
material plastic laminated per mil p 18177 and plastic laminated, grade G10, L-P-509; 8.000 in. lg; 8.000 in. w; 6.525 in. h; four 0.206 in. dia min to 0.212 in. dia max mtg holes; two 0.235 in. dia min to 0.241 in. dia max mtg holes; four 0.210 in. dia min to 0.216 in. dia max mtg holes, 0.500 in. dia cbore, 0.180 in. deep far side; thirteen 0.093 in. dia min to 0.099 in. dia max mtg holes
An item fabricated from electrically nonconductive material specifically designed to provide a support for mounting an electrical and/or an electronic component such as a semiconductor device, relay, or resistor into the next higher assembly. It isolates the component from the mounting surface of the next higher assembly, it may act as a strain relief to avoid damage to the component seal, and it may permit soldering of the component to the next higher assembly without damage. It includes holes, notches, or other provisions for physical alignment and spacing of electrical leads and/or other mounting facilities projecting from the component it mounts. It may also afford protection from shock or vibration. It may be either nonthermally conductive which protects the component from temperature changes in the next higher assembly or it may be thermally conductive which permits heat generated in the component to be drained out to a heat sink. For items whose function is electrical insulation only, see insulator, (as modified). Excludes holder, (as modified); retainer, (as modified), and spacer, plate.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Defense supply center columbus, columbus, oh 43218
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.