Serving our customers with quality and safety first.
10.750in. ⁓10-3/4"
3.750in.
watertight
T-21
miniature screw
green
transformer and threaded entrance and box cover
4 switch and 1 light
inclosure matl:plastic; assy o/a h:3.840 in. max; assy o/q w:3.750 in. nom; assy o/a l:11.500 in. nom; switch type:1st variation rotary, 1st var push, 1st var push, 1st var rotary; switch current rating in amps:1st variation 30, 1st var 60, 1st var 60, 1st var 30; switch current type:all four 1st variations are ac/dc; lamp:included; inclosure type:BOX-Cover; ctact arrgt:1st variation spring return to center from clockwise and counterclockwise, 1st var 2 circuit, double make, double break, 1st var 2 circuit, couble make, double break, 1st var maintained contact, center and clockwise; voltage rating:all four 1st variations are 115 min. and 440 max. v; primary voltage rating:117 v nom; secondary voltage rating:5 v nom; luminous actuator:not included; threaded entrance qty:1; mntg config:four 0.281 in. dia. mtg holes on 3 in. x 10.750 in. mtg cntrs; thread location:internal; inclosure surf. treat.:any acceptable; opening thread size:1 in. 11-1/2
plastic
rectangular
An electrical device consisting of a switch (1) and two or more lights, or two or more switches and two or more lights, mounted on a common mounting. The lights are not intended for illumination but are present for the purpose of indication. Each item may be separable and capable of functioning individually, or the items may be fabricated into a common inseparable body, incapable of functioning individually. It may include wall plate or box cover and it may be complete with box. Excludes push, pull, push-pull, and toggle switches with a lamp mounted integrally in the actuator.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) postal regulations, (b) department of transportation regulations, (c) civil air regulations, (d) uniform freight classification rules, (e) national motor freight classification rules, (f) american truckers' association rules, (g) other applicable carriers' rules, (h) military air regulations for dangerous materials. consolidation of shipments. all exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. dangerous goods shall be prepared for shipment according to applicable department of transportation (dot) regulations and international regulations in effect at time of shipment. shipment by parcel post must comply with postal regulations.
Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.